3-3. Remote 14 Receptacle Information

A J

B K I

C L N H

D M G

EF

 

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

 

 

 

B

Contact closure to A completes 24 volts ac

 

 

contactor control circuit.

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

 

 

 

J

Contact closure to I completes 115 volts ac

 

 

contactor control circuit.

 

C

Output to remote control; 0 to +10 volts dc, +10

 

 

volts dc in MIG mode.

REMOTE

D

Remote control circuit common.

OUTPUT

E

0 to +10 volts dc input command signal from

CONTROL

 

 

remote control.

 

M

CC/CV select (CC/CV models).

A/V

F

Current feedback; +1 volt dc per 100 amperes.

 

 

AMPERAGE

H

Voltage feedback; +1 volt dc per 10 output recep-

VOLTAGE

 

tacle volts.

 

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

 

*The remaining sockets are not used.

3-4. Optional 115 Volts AC Duplex Receptacle And Circuit Breakers

1 115 V 10 A AC Receptacle

Power is shared between duplex receptacle and Remote 14 recep- tacle (see Section 3-3).

 

2

Circuit Breaker CB1

1

3

Circuit Breaker CB2

 

 

CB1 protects duplex receptacle and 115 volts ac portion of Remote 14 receptacle from overload.

CB2 protects 24 volts ac portion of Remote 14 receptacle from overload.

Press button to reset breaker.

2 3

ST-801 245-A

OM-2208 Page 13

Page 17
Image 17
Hobart Welding Products OM-2208 manual Remote 14 Receptacle Information, Socket Information