OM-2208 Page 13
3-3. Remote 14 Receptacle Information
Socket* Socket Information
24 VOLTS AC A24 volts ac. Protected by circuit breaker CB2.
AJ
KI

24 VOLTS AC

BContact closure to A completes 24 volts ac
contactor control circuit.
BKI
CLNH 115 VOLTS AC I115 volts ac. Protected by circuit breaker CB1.
C
NH
DMG
EF

115 VOLTS AC

JContact closure to I completes 115 volts ac
contactor control circuit.
COutput to remote control; 0 to +10 volts dc, +10
volts dc in MIG mode.
REMOTE DRemote control circuit common.

OUTPUT

CONTROL E0 to +10 volts dc input command signal from
remote control.
MCC/CV select (CC/CV models).
A/V FCurrent feedback; +1 volt dc per 100 amperes.
A/V

AMPERAGE

VOLTAGE HVoltage feedback; +1 volt dc per 10 output recep-
tacle volts.
GCircuit common for 24 and 115 volts ac circuits.
GND KChassis common.
*The remaining sockets are not used.
ST-801 245-A
1 115 V 10 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 3-3).
2 Circuit Breaker CB1
3 Circuit Breaker CB2
CB1 protects duplex receptacle
and 115 volts ac portion of Remote
14 receptacle from overload.
CB2 protects 24 volts ac portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
2 3
1
3-4. Optional 115 Volts AC Duplex Receptacle And Circuit Breakers