4-3. Meter Functions For CC/CV Model

NOTE

The meters display the actual weld output values for approximately three seconds after the arc is broken.

Mode

 

Meter Reading At Idle

 

Meter Reading While Welding

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Scratch

 

80.0

 

 

85

 

 

10.3

 

 

85

 

Start TIG

 

 

 

 

 

 

 

 

 

Actual Volts (OCV)

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Lift-Arc TIG

 

7.0

 

 

85

 

 

10.3

 

 

85

 

 

 

Actual Volts

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

TIG

 

 

 

 

85

 

 

10.3

 

 

85

 

 

 

Blank

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

MIG

 

24.5

 

 

 

 

 

24.5

 

 

250

 

 

 

Preset Volts

 

Blank

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Pulsed

 

PPP

 

 

PPP

 

 

24.5

 

 

250

 

MIG

 

 

 

 

 

 

 

 

 

Pulse Display

Pulse Display

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

CC

 

 

 

 

85

 

 

24.5

 

 

85

 

 

 

Blank

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Stick

 

80.0

 

 

85

 

 

24.5

 

 

85

 

 

Actual Volts (OCV)

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

V-Sense

 

80.0

 

 

 

 

 

24.5

 

 

250

 

Feeder

 

 

 

 

 

 

 

 

 

 

Flashes OCV And Preset

 

Blank

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

4-4. Mode Switch Settings For CC/CV Model

NOTE

The Stick and CC modes provide the Adaptive Hot Startfeature, which automatically increases the output amperage at the start of a weld should the start require it. This eliminates electrode sticking at arc start.

Mode Switch Setting

Process

Output On/Off Control

 

 

 

Scratch Start TIG

GTAW

Electrode Hot

 

 

 

Lift-Arc TIG

GTAW – See Section 4-7

Electrode Hot

 

 

 

TIG

GTAW With HF Unit, Pulsing Device, Or Remote Control

At Remote 14

 

 

 

MIG

GMAW

At Remote 14

 

 

 

Pulsed MIG

GMAW-P (Requires an external pulsing device.)

At Remote 14

 

 

 

CC

Stick (SMAW) With Remote On/Off

At Remote 14

 

 

 

Stick

SMAW

Electrode Hot

 

 

 

V-Sense Feeder

MIG (GMAW) With Voltage Sensing Wire Feeder

Electrode Hot

 

 

 

OM-2208 Page 18

Page 22
Image 22
Hobart Welding Products OM-2208 manual Meter Functions For CC/CV Model, Mode Switch Settings For CC/CV Model