4-3. Meter Functions For CC/CV Model
NOTE
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode |
| Meter Reading At Idle |
| Meter Reading While Welding | ||||||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
Scratch |
| 80.0 |
|
| 85 |
|
| 10.3 |
|
| 85 |
|
Start TIG |
|
|
|
|
|
|
|
| ||||
| Actual Volts (OCV) | Preset Amps |
| Actual Volts | Actual Amps | |||||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
| 7.0 |
|
| 85 |
|
| 10.3 |
|
| 85 |
| |
|
| Actual Volts | Preset Amps |
| Actual Volts | Actual Amps | ||||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
TIG |
|
|
|
| 85 |
|
| 10.3 |
|
| 85 |
|
|
| Blank | Preset Amps |
| Actual Volts | Actual Amps | ||||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
MIG |
| 24.5 |
|
|
|
|
| 24.5 |
|
| 250 |
|
|
| Preset Volts |
| Blank |
| Actual Volts | Actual Amps | |||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
Pulsed |
| PPP |
|
| PPP |
|
| 24.5 |
|
| 250 |
|
MIG |
|
|
|
|
|
|
|
| ||||
| Pulse Display | Pulse Display |
| Actual Volts | Actual Amps | |||||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
CC |
|
|
|
| 85 |
|
| 24.5 |
|
| 85 |
|
|
| Blank | Preset Amps |
| Actual Volts | Actual Amps | ||||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
Stick |
| 80.0 |
|
| 85 |
|
| 24.5 |
|
| 85 |
|
| Actual Volts (OCV) | Preset Amps |
| Actual Volts | Actual Amps | |||||||
|
|
|
|
|
|
|
|
| ||||
|
| V |
| A |
| V |
| A | ||||
| 80.0 |
|
|
|
|
| 24.5 |
|
| 250 |
| |
Feeder |
|
|
|
|
|
|
|
|
| |||
| Flashes OCV And Preset |
| Blank |
| Actual Volts | Actual Amps | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
4-4. Mode Switch Settings For CC/CV Model
NOTE
The Stick and CC modes provide the Adaptive Hot Start feature, which automatically increases the output amperage at the start of a weld should the start require it. This eliminates electrode sticking at arc start.
Mode Switch Setting | Process | Output On/Off Control |
|
|
|
Scratch Start TIG | GTAW | Electrode Hot |
|
|
|
GTAW – See Section | Electrode Hot | |
|
|
|
TIG | GTAW With HF Unit, Pulsing Device, Or Remote Control | At Remote 14 |
|
|
|
MIG | GMAW | At Remote 14 |
|
|
|
Pulsed MIG | At Remote 14 | |
|
|
|
CC | Stick (SMAW) With Remote On/Off | At Remote 14 |
|
|
|
Stick | SMAW | Electrode Hot |
|
|
|