OM-2208 Page 19

4-5. Meter Functions For CC Model

The meters display the actual weld output values for approximately three seconds

after the arc is broken.

NOTE
Mode Meter Reading At Idle Meter Reading While Welding
Scratch
Start TIG
VA
Actual Volts (OCV) Preset Amps
80.0 85
Actual Volts Actual Amps
VA
10.3 85
Lift-Arc TIG
Actual Volts Preset Amps
VA
7.0 85
Actual Volts Actual Amps
VA
10.3 85
TIG
Blank Preset Amps
VA
85
Actual Volts Actual Amps
VA
10.3 85
Stick
(Stiff Or Soft) Actual Volts (OCV) Preset Amps
VA
80.0 85
Actual Volts Actual Amps
VA
24.5 85

4-6. Mode Switch Settings For CC Model

The Stick modes provide the Adaptive Hot Start feature, which automatically

increases the output amperage at the start of a weld should the start require it. This

eliminates electrode sticking at arc start.

NOTE
Mode Switch Setting Process Output On/Off Control
Scratch Start TIG GTAW Electrode Hot
Lift-Arc TIG GTAW With Lift-Arc Start See Section 4-7 Electrode Hot
TIG GTAW With HF Unit, Pulsing Device, Or Remote Control At Remote 14
Stick (Stiff) SMAW When A Stiff Arc Characteristic Is Desired Electrode Hot
Stick (Soft) SMAW When A Soft Arc Characteristic Is Desired Electrode Hot