SECTION 3 – INSTALLATION
| Amperes Input at |
|
|
|
| Rated |
| ||
| Rated Output, |
|
|
| Plasma |
| |||
|
|
|
| Cutting |
| ||||
| 60 Hz, |
|
|
|
| ||||
| 115 V | 230 V | Plasma | Gas Flow/ | Capacity | Max | |||
|
|
| |||||||
Rated Output | 115 V | 230 V | KVA/KW | KVA/KW | Gas | Pressure | at 10 IPM | OCV | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 115 VAC |
| |
|
|
|
|
| Air Or | 4.5 CFM | Input: 1/4 in |
| |
21 A at 88 Volts DC At | 25.3 max; | 12.6 max; | 2.9 KVA | 2.9 KVA | (129 L/min) | (6 mm); | 265 Volts | ||
Nitrogen | |||||||||
35% Duty Cycle | 15 eff | 7.5 eff | 2.2 KW | 2.2 KW | At 60 PSI | 230 VAC | DC | ||
Only | |||||||||
|
|
|
|
| (414 kPa) | Input: 5/16 in |
| ||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| (8 mm) |
| |
|
|
|
|
|
|
|
|
|
NOTE
If the unit is operated from a 30 ampere, 115 volt circuit or a 15 ampere, 230 volt circuit, a different input power plug must be installed on the power cord. See Section
| Amperes Input at |
|
|
|
| Rated |
| ||
| Rated Output, |
|
|
| Plasma |
| |||
|
|
|
| Cutting |
| ||||
| 60 Hz, |
|
|
|
| ||||
| 115 V | 230 V | Plasma | Gas Flow/ | Capacity | Max | |||
|
|
| |||||||
Rated Output | 115 V | 230 V | KVA/KW | KVA/KW | Gas | Pressure | at 10 IPM | OCV | |
|
|
|
|
|
|
|
|
| |
27 A at 91 Volts DC At | 33.6 max; | 16.8 max; | 3.8 KVA | 3.8 KVA |
|
| 115 VAC |
| |
35% Duty Cycle | 19.9 eff | 9.9 eff | 3.1 KW | 3.1 KW |
|
|
| ||
|
|
|
|
| Air Or | 4.5 CFM | Input: 1/4 in |
| |
21 A at 88 Volts DC At | 25.3 max; | 12.6 max; | 2.9 KVA | 2.9 KVA |
| ||||
(129 L/min) | (6 mm); | 265 Volts | |||||||
Nitrogen | |||||||||
60% Duty Cycle | 19.6 eff | 9.8 eff | 2.2 KW | 2.2 KW | At 60 PSI | 230 VAC | DC | ||
Only | |||||||||
|
|
|
|
| (414 kPa) | Input: 5/16 in |
| ||
17 A at 87 Volts DC At | 20.9 max; | 10.5 max; | 2.4 KVA | 2.4 KVA |
|
| |||
|
| (8 mm) |
| ||||||
100% Duty Cycle | 20.9 eff | 10.5 eff | 1.8 KW | 1.8 KW |
|
|
| ||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
3-3. Specifications For CE Model
| Amperes Input at |
|
|
|
|
|
| ||
| Rated Output, |
|
|
|
|
|
| ||
| 50 Hz, |
|
|
| Plasma |
|
| ||
|
|
|
|
|
| ||||
|
|
|
|
| Plasma | Gas Flow/ | Max | IP | |
Rated Output | 115 V | 230 V | KVA | KW | Gas | Pressure | OCV | Rating | |
|
|
|
|
|
|
|
|
| |
115 VAC Input: |
|
|
|
|
|
|
|
| |
20 A @ 89 Volts DC |
|
| 115 VAC | 115 VAC |
|
|
|
| |
(20 A Input Circuit); |
|
|
|
|
|
| |||
|
| Input: 3.1 | Input: 2.4 | Air Or | 4.5 CFM |
|
| ||
25 A @ 89 Volts DC |
|
|
|
| |||||
26 | 17 | (0.05*) | (0.04*) | (129 L/min) |
|
| |||
(30 A Input Circuit); | Nitrogen | 265 Volts DC | 23 | ||||||
(0.4*) | (0.2*) | 230 VAC | 230 VAC | At 60 PSI | |||||
230 VAC Input: | Only |
|
| ||||||
|
| Input: 4.0 | Input: 3.1 | (414 kPa) |
|
| |||
25 A @ 89 Volts DC; |
|
|
|
|
| ||||
|
| (0.05*) | (0.04*) |
|
|
|
| ||
35% Duty Cycle In All |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
Cases |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
*While idling |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|