3-8. Setting Input Voltage Selector Switch And Connecting Input Power

3

Tools Needed:

 

115V

230V

 

 

S-176 481-A

 

2

 

1

. If input voltage selector switch is set to a different

voltage when unit is plugged in and turned on, the

Rear Of Unit

unit will go into a protective shutdown mode. To re-

 

 

cover normal unit operation from this condition,

4

proceed as follows:

 

 

S Place Power Switch in OFF position.

S Unplug input power cord.

S Place input voltage selector switch in correct position.

S Wait 60 seconds before reconnecting input power cord and turning on unit.

Check input voltage available at site.

1 Input Voltage Selector Switch

Switch is accessible through slot in rear panel.

2 Changeover Switch Label

Look at label to find correct switch position.

Move switch to match input voltage.

3 Supplied 115 VAC Plug

If plug does not match voltage at re- ceptacle or type of receptacle, install suitable plug according to Section 3-9.

YBe sure input power connec- tion meets all applicable na- tional, regional, and local electrical codes.

4115 Or 230 VAC Receptacle

(115 VAC Shown)

YTo use rated output (see specifications), connect the unit to an individual branch circuit capable of carrying the effective (eff) current for the output being used. The unit must have a properly sized plug installed and the circuit must be protected by proper- ly sized fuses or circuit break- ers.

Connect plug to proper receptacle. Be sure receptacle can handle load.

801 304-C / 801 319-C

3-9. Installing Alternative Plug

This procedure is necessary if the unit is to be connected to a 230 VAC receptacle, or to a 115 VAC receptacle that requires a plug that is different from the supplied plug.

See Section 3-8 for instructions on setting input voltage selector switch for proper voltage.

2

3

6

1 7

4

5

1 Supplied 115 VAC Plug

Cut cord close to plug.

2Alternative PLug (230 VAC Plug Shown)

3Load 1 (Brass) Terminal

4Load 2 (Brass) Terminal

5Ground (Green) Terminal

6Outer Shell

7Cord Grip

Strip cord jacket back enough to separate conductors. Strip conduc- tors enough to make good contact with plug terminals. Make plug con- nections and reinstall outer shell and cord grip. Tighten assembly screws onto shell. Do not overtighten.

Tools Needed:

Ref. 801 305-A / 801 611

OM-2210 Page 15

Page 19
Image 19