3-7. Connecting Work Clamp And Gas/Air Supply
1
2
3
64
From Gas/Air Supply
5
Tools Needed: 5/8,
1Work Clamp
2Workpiece
Connect work clamp to a clean,
.Use only clean, dry air with 70 to 150 psi (483 to 1034 kPa) pressure.
3Air Filter/Regulator
4Gas/Air Inlet Opening
5Hose
6Teflon Tape
Obtain hose with 1/4 NPT right- hand thread fitting. Wrap threads with teflon tape (optional) or apply pipe sealant, and install fitting in opening. Route hose to gas/air supply.
Adjust gas/air pressure according to Section
Ref. 801