3-7. Connecting Work Clamp And Gas/Air Supply

1

2

3

64

From Gas/Air Supply

5

Tools Needed: 5/8, 1-1/8 in

1Work Clamp

2Workpiece

Connect work clamp to a clean, paint-free location on workpiece, as close to cutting area as possible.

.Use only clean, dry air with 70 to 150 psi (483 to 1034 kPa) pressure.

3Air Filter/Regulator

4Gas/Air Inlet Opening

5Hose

6Teflon Tape

Obtain hose with 1/4 NPT right- hand thread fitting. Wrap threads with teflon tape (optional) or apply pipe sealant, and install fitting in opening. Route hose to gas/air supply.

Adjust gas/air pressure according to Section 4-1.

Ref. 801 319-C / Ref. 801 306-C