5-3. Torch And Work Cable Connections
8
9
2
5
11
613
7 | 10 |
3
1
4
12
Tools Needed:
5/8 in
If torch or work cable needs to be removed or replaced, proceed as follows:
Turn power Off, and disconnect in- put power plug from receptacle. Re- move top and screws holding front panel in place. Without disconnect- ing any plugs, move front panel to allow access.
Torch Connections
1Strain Relief Clamp
2Torch Cable
Insert cable through strain relief clamp.
3Gas Connector
4Gas Valve
Install gas connector onto gas valve.
5Plug PLG18
6Safety Control Board PC2
7Receptacle RC18
Connect PLG18 to RC18. Route leads along existing lead bundle.
8Female Friction Terminals
9Male Friction Terminal
10Power Control Board PC1
11Receptacle RC4
Connect female terminals to leads 23 and 24 from RC4 (connect to either lead). Connect male terminal to lead 25 from RC4. Route leads as shown.
Work Cable Connections
12 Strain Relief Clamp
Insert work clamp lead through strain relief clamp.
13 Receptacle RC6
Connect work clamp lead to lead 20 from RC6 (leads not shown). Route leads along existing lead bundle.