5-3. Reinstalling Amperage Adjustment Indicator
1
5
6
2
7
3
4
(67 mm)
3
Viewed from right side of unit.
2
Proper alignment of pointer and crank handle.
YTurn Off welding power source and disconnect input power.
1 Wrapper
Remove wrapper from unit.
2Crank Handle
3Shunt Shaft
4Transformer And Shunt (Located Inside Unit)
Insert crank handle onto shunt shaft protruding through front panel and turn crank handle to adjust shunt to
Remove crank handle.
5 Pinion Gear
Install pinion gear onto front panel making sure
6 Pointer Gear
Install pointer gear overtop of pinion gear and rotate so pointer is indicat- ing 140 Amps (see example).
Install crank handle overtop the sta- tor/pinion gear assembly with the handle straight down. It may be necessary to turn the handle slight- ly so vertical alignment is possible.
7 Securing Screw
Install securing screw through han- dle, into threaded hole in shunt shaft. Tighten securely.
YInstall wrapper before turning On power.
Tools Needed:
5/16, 3/8 in
804