Installation Instructions
Field Wiring Connections
PREPARATION
1Prepare wires for
2Ensure terminal block screws are loosened sufficiently to permit easy access for wire ends. Insert stripped wire ends into the clamp aperture and tighten screws. Do not over tighten as this may damage the terminal block.
3A maximum of 0.5 Amps may be supplied by any output. Check the inrush current of your solenoid coils before connecting more than two valves to any one station.
Terminal Block Layout
The terminal block is laid out as follows:
Fuse located under battery cover.
| GLOSSARY |
|
| AC | 24VAC Power Supply |
| COM | Common valve wire input |
| PUMP | Master valve or pump start active wire |
| ST1 to ST6 | Station (Valve) active wire connection |
|
|
|
PAGE 18 |
|
Installation Instructions
Power Supply Connections
The controller itself can run off a 240V AC to 24V AC external transformer..
It is recommended that the transformer is not connected to a 240V AC supply which is also servicing or supplying motors (i.e. Air conditioners, pool pumps, refrigerators, etc.) Lighting circuits are suitable as a power source.
Connections to the unit are as follows:
Connection Of Valves
Up to two 24VAC Solenoid Valves can be connected to each station output and wired back to the common (COM) thus:
Valve wires enter the controller | PAGE 19 |
through the rear |