System Options
Note: Before operating the thermostat, the “System Type” and “System Mode” must be configured.
The thermostat can be configured with the following system options:
System | *Conventional | Dual Fuel Heat Pump1 | Zone Control | Heat Pump |
Type |
|
|
|
|
| *Auto Changeover | Auto Changeover | Auto Changeover | Auto Changeover |
| No Fan With Heat | Fan On With Heat | No Fan With Heat | Fan On With Heat |
| Auto Changeover | Manual Changeover | Auto Changeover | Manual Changeover |
| Fan On With Heat | Fan On With Heat | Fan On With Heat | Fan On With Heat |
| Manual Changeover |
| Manual Changeover |
|
System | No Fan With Heat |
| No Fan With Heat |
|
Manual Changeover |
| Manual Changeover |
| |
Mode |
|
| ||
Fan On With Heat |
| Fan On With Heat |
| |
|
|
| ||
| Heat Only |
| Heat Only |
|
| No Fan With Heat |
| No Fan With Heat |
|
| Heat Only |
| Heat Only |
|
| Fan On With Heat |
| Fan On With Heat |
|
| Cool Only |
| Cool Only |
|
1When configured, an additional Installer Setup menu item (Balance Setpoints) is added to the list.
Program Options
This thermostat has been preprogrammed with energy saving program schedules in accordance with the ENERGY STAR® program. When used with a remote system, HAI recommends that the Program Mode be configured as “None” or “Occupancy”. This will disable the internal program schedules.
The program options setting sets the method for scheduling temperature change commands.
Program
Mode
*Schedule: Program setpoints are based on time of day and day of week.
None: The internal program schedule is disabled. Use this when connected to a remote system for temperature change commands.
Occupancy: Program setpoints are based on the occupancy status of a remote system. Status options are Day, Night, Away, and Vacation. This mode is also used with a remote setback switch. Note: A remote system or switch is required.
Calibration Offset
This item is used to raise or lower the current temperature reading from the onboard temperature sensor by .5 degree Fahrenheit or .25 degree Celsius. The default setting is 0.00.
Cool/Heat Limit
These items are used to limit the desired temperature settings in cool and heat mode. The desired cool setting can never be set below the “Cool Setpoint Min” setting and the desired heat setting can never be set above the “Heat Setpoint Max” setting. The default setting for cool is 51°F. The default setting for heat is 91°F.
16