Instructions for Use

CAUTION:

All servicing of this ProClipper must be performed by authorized HoMedics service personnel only.

Caution – Please read all instructions carefully before operating.

If you have any concerns regarding your health consult your doctor before using this product.

Individuals with pacemakers should consult a doctor before use.

Never leave the appliance unattended, especially if children are present.

Never cover the appliance when it is in operation.

Do not use this product for more than 20 minutes at a time.

Extensive use could lead to the products excessive heating

and shorter life. Should this occur, discontinue use and allow the unit to cool before operating.

Never use this product directly on swollen or inflamed areas or skin eruptions.

Never use this product while in bed.

This product should never be used by any individual suffering from any physical ailment that would limit the user’s capacity to operate the controls.

This unit should not be used by children without adult supervision.

.05" or 1.2mm

Instructions for Use

Blade Alignment

Your clippers were carefully examined to ensure that the blades were oiled and aligned before leaving our factory.

Blades must be realigned if they have been removed for cleaning or replacement.

To realign the blades, simply match the upper and bottom blades teeth up, point for point. (End of top blade teeth should be approximately .05” or 1.2mm back from bottom blade. Compare your clipper blades with the sketch.)

If blade alignment is incorrect, add a few drops of oil to the blades, turn clipper on for a few moments, turn off and unplug. Loosen screws slightly and adjust. Tighten screws after blade is aligned.

Oil

To maintain your clipper in peak condition, the blades should be oiled before every haircut.

Do not use hair oil, grease, oil mixed with kerosene or any solvent. The solvent will evaporate and leave a thick oil which may slow down the blades motion.

Power Screw

The power screw permits you to adjust the power. It has been adjusted before leaving the factory. However, if the voltage in your home is low, you may need to re-adjust it.

To adjust, use a screwdriver or a thin coin to turn power screw in clockwise direction until the arm strikes the coil, making a noise. Then slowly turn power screw out (counter-clockwise) just until noise stops. This is maximum power setting.