SERVICING YOUR GENERATOR

SPARK ARRESTER SERVICE

The spark arrester must be serviced every 100 hours to keep it functioning as designed.

If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester.

1.Remove the four 6 mm cap nuts, and remove the rear cover.

2.Remove the four 6 mm bolts, and remove the upper muffler

protector.

6 mm BOLTS

6 mm BOLTS

 

WASHER

UPPER MUFFLER

 

PROTECTOR

 

REAR COVER

 

6 mm CAP NUTS

3.Remove the four 8 mm bolts, and remove the rear handle.

4.Remove the four 6 mm bolts, and remove the rear under plate.

5.Remove the lower muffler protector.

8 mm BOLTS

LOWER MUFFLER

PROTECTOR

REAR HANDLE

WASHER

REAR UNDER PLATE 6 mm BOLTS