Honda Power Equipment DCX3000 manual Generator Problems

Models: DCX3000

1 76
Download 76 pages 52.79 Kb
Page 58
Image 58

TAKING CARE OF UNEXPECTED PROBLEMS

GENERATOR PROBLEMS

No Power at the

Possible Cause

Correction

DC Output Coupler

 

 

1. Check output

Output indicator is

Check DC load.

and overload

OFF, and overload

Stop and restart

indicator.

indicator is ON.

the engine.

 

 

Check the cooling

 

 

air inlet. Stop and

 

 

restart the engine.

2. Check UPS

Setting different

Turn off the engine

battery string

voltage connected

switch and set the

voltage

to the UPS.

voltage selector

requirement.

 

switch to the same

 

 

battery string

 

 

voltage of the UPS

 

 

(p. 14).

3. Check the power

Power cord

Make sure

cord.

connected to UPS

generator positive

 

battery string in

output side of

 

reverse polarity.

coupler is

 

 

connected to

 

 

positive terminal

 

 

of UPS battery

 

 

string.

4. Take generator

Faulty generator.

Replace or repair

to an authorized

 

faulty components

Alphagen

 

as necessary.

servicing dealer,

 

 

or refer to shop

 

 

manual.

 

 

56

Page 58
Image 58
Honda Power Equipment DCX3000 manual Generator Problems, No Power at Possible Cause Correction DC Output Coupler