Diagnostics for Honeywell Control Continued-
LED Status | Control Status |
| Probable Cause | |
Six flashes and three | Water leak detected by | 1. Excessive amount of water in | ||
accessory module (some | ||||
second pause |
| drain pan/water dam. | ||
models). |
| |||
|
|
| ||
|
|
|
| |
|
| 1. | Verify control is not wet or | |
|
|
| physically damaged. | |
Seven flashes and three | Gas valve electronic fault | 2. | Turn set point knob to "OFF" | |
second pause. | detected. |
| position. Turn set point knob to | |
| "PILOT" position and light pilot. | |||
|
|
| ||
|
| 3. | Replace gas valve if seven | |
|
|
| flash error persists. | |
|
| 1. | Pilot valve stuck in open | |
|
|
| position | |
Eight flashes and three |
| 2. | Turn set point knob to "OFF" | |
False pilot flame present. |
| position. Turn set point knob to | ||
second pause |
| |||
|
| "PILOT" position and light pilot. | ||
|
|
| ||
|
| 3. | Replace gas valve if eight flash | |
|
|
| error persists. |
28