Honeywell 238-47969-00A, Gas Water Heater Diagnostics for Honeywell Control Continued

Models: Gas Water Heater 238-47969-00A

1 32
Download 32 pages 57 Kb
Page 28
Image 28

Diagnostics for Honeywell Control Continued-

LED Status

Control Status

 

Probable Cause

Six flashes and three

Water leak detected by

1. Excessive amount of water in

accessory module (some

second pause

 

drain pan/water dam.

models).

 

 

 

 

 

 

 

 

 

 

1.

Verify control is not wet or

 

 

 

physically damaged.

Seven flashes and three

Gas valve electronic fault

2.

Turn set point knob to "OFF"

second pause.

detected.

 

position. Turn set point knob to

 

"PILOT" position and light pilot.

 

 

 

 

 

3.

Replace gas valve if seven

 

 

 

flash error persists.

 

 

1.

Pilot valve stuck in open

 

 

 

position

Eight flashes and three

 

2.

Turn set point knob to "OFF"

False pilot flame present.

 

position. Turn set point knob to

second pause

 

 

 

"PILOT" position and light pilot.

 

 

 

 

 

3.

Replace gas valve if eight flash

 

 

 

error persists.

28

Page 28
Image 28
Honeywell 238-47969-00A, Gas Water Heater instruction manual Diagnostics for Honeywell Control Continued