PIN + ent
0 = OMIT ZONES [ent] to Select
8
8 = CODES [ent] to Select
ent
CODES
1 = User Codes
ent
001 USER
L3 A1_______
ent
[ent] to Select 3 = Modify PIN
3
[ent] to Select
3 = Modify Name
>A ent
001 NAME USER_ EFG HIJKLMNØö0 P
ent
[ent] to Select 4 = Time Zone
ent
[ent] to Select 0 = OFF
Use the A key to step through the four time zone options.
ent
• Quick Menu
All user codes default to the quick menu. This menu is made up of a selection of ten options (0 – 9) from the menu options 11 – 49. The user code type controls access to the quick menu. Any user can be upgraded from the quick menu to the full menu by assigning a * to the user while the Modify Level option is accessed. Therefore a user with a type *2.5 would have access to the full menu from options 11 – 32. No code can access both menus.
Note: The master manager code defaults to the full menu.
Modify Name
This allows a name to be assigned to the user (maximum 6 characters). Each of the user codes default to the name USER and the manager defaults to MGR. The manager name cannot be changed. On selecting the Modify Name option, a section of the
Time Zone
Managers can allocate time zones to user PINs when TIMERS have been programmed by the engineer. Time zones are used to disable the user PIN during the times (ON to OFF) programmed in TIMER A and B.
When 4 = TIME ZONE displays, press the ent key . Using the A> key select the time zones option to be allocated to the PIN. The following time zones options are available:
0=OFF 1=TIMER A 2=TIMER B 3=TIMER A+B
The times assigned to Timer A and Timer B can be viewed using option 45 Timer Control. No access will be granted if a code, assigned to 1=Timer A, 2=Timer B or 3= Timer A+B is entered out with the assigned times, an Illegal Code event is recorded in the log and any outputs programmed as Illegal Code are activated.