Arming the System (cont)

Arming the System (cont)

WHEN THE SYSTEM IS NOT READY

If the system is not ready to be armed, the READY/light will be off and the

display will show which zone or zones are not ready. The following conditions will be indicated by the zone lights (LED keypad) or described on the display:

Fast Blink

Alarm or tamper condition

Slow Blink/Low Intensity ...

Bypass

Slow Pulse

Trouble, problem with RF receiver, or low battery

Solid On

Zone faulted

Example: If the READY/light is not lit and the Zone 1 light is solid on, an

alarm sensor on Zone 1 is faulted. This might mean that a door is open or someone is walking in view of a motion sensor. Check all sensors on Zone 1 and resolve the problem. When all sensors are restored, the READY/light will come on and the

zone light will go out. In this example, the display shows:

NOT READY

and

NOT RDY

ZN 1

FRONT DOOR

 

Determine which zone or zones are not ready, resolve the problem, and arm the system normally. If the problem cannot be resolved, you may bypass the zone that is not ready. Bypassing should only be done if the problem on the zone cannot be resolved, OR if you intentionally wish to leave the zone disarmed. For example, you would leave the zone disarmed if you plan to keep the window open for ventilation. Zones that are bypassed are not protected when the system is armed. See TO BYPASS A ZONE on page 13 for a description of the procedure.

TO ARM THE SYSTEM AND STAY INSIDE

To arm the perimeter portion of your burglar alarm and move around freely inside the premises, use the STAY mode.

Check to make sure the system is ready. When it is ready, press:

STAY /

followed by your user code.

When the system has been armed successfully, the ARMED/WHEN THE SYSTEM IS NOT READY (STAY) light is lit and the following is displayed:

LCD Keypad:

ON: STAY

Fixed-Word Keypad:

STAY/Manual background

LED Keypad:

ARM/Manual background and STAY/Manual background LEDs lit

REMEMBER: You must disarm the system or press STAY /

to initiate

the “quick exit” if you want to open the door or leave the premises after the exit time has expired. Quick Exit restarts the exit time without disarming the system.