Specifications
2.Specifications
2.1Specifications for 04905 Series
Parameter | Description |
|
|
Cell Constant | 04905 Series: 0.01, 0.1, 1.0, 10 and 50 as |
| specified |
Electrode Material | Nickel, Platinum or Monel as specified |
|
|
Maximum Pressure Limit | 1724 kPa @ 140°C (250 psig @ 284°F) |
|
|
Maximum Continuous Temperature Limit | 140°C (284°F) |
| For immersion applications: |
| 80°C (176°F) |
Materials of Construction | Cell Body: PES (polyethersulfone) |
| Support Fittings: Ryton |
| Electrodes: Nickel, Platinum or Monel as specified |
| Quick Disconnect Receptacle: Stainless Steel |
|
|
Cable Options | Leadwire: PVC insulated 22 gage cable, 0.245” |
| OD, 20 and 50 feet lengths available. |
| Quick Disconnect Option |
| Mating cables must be purchased from Honeywell |
| Universal Head (Aluminum) |
|
|
Weight | Approximately 1 lb (0.45 kg) |
| If using universal head: |
| 3 lb (1.35 kg) |
Approvals | Manufactured to comply with ASME boiler and |
| pressure vessel code Section III, Div.1, |
| CRN #0F11607.5C |
|
|
Insertion | 1” NPT male, Schedule 40 |
|
|
Flow Chamber | Inlet: 3/4" MNPT |
| Outlet: 3/4" FNPT |
|
|
Insertion Depth | 5” to 7” (127 to 178 mm) depending on cell |
| constant |
Overall Length | Approximately 6 to 8” (152 to 203 mm) |
| If using universal head: |
| 10 to |