Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for the ASCII character that will trigger the

delay ASCII Conversion Chart (Code Page 1252), beginning on page A-3.

Delay Length

Character to Trigger Delay

To remove this delay, scan the Delay Length bar code, and set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.

Interfunction Delay

An interfunction delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each control character in the message string. Scan the Interfunction Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.

 

 

Prefix

 

Scanned Data

Suffix

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STX

 

1

HT

 

2

3

4

5

 

CR

 

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interfunction Delays

 

 

 

Interfunction Delay

To remove this delay, scan the Interfunction Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.

Intermessage Delay

An intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission. Scan the Intermessage Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.

1st Scan Transmission 2nd Scan Transmission Intermessage Delay

Intermessage Delay

To remove this delay, scan the Intermessage Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside the back cover of this manual.

4 - 4