Five wires connected to the old thermostat

Your new thermostat has a factory-installed metal jumper between the R and Rc terminals (Fig. 15). Remove the jumper before wiring the R and Rc terminals.

JUMPER (FACTORY-

Fig. 15

INSTALLED). REMOVE

IF 5-WIRE SYSTEM

 

c

 

R

 

R

 

 

G

Y

W

M20127

Old thermostat terminals that do not match new thermostat terminals

Use the table below to wire the new thermostat.

Old thermostat

Connect to new

 

terminal

thermostat terminal

Description

 

 

 

R, RH, 4, V

R*

Power

 

 

 

Rc, R

Rc*

Power for cooling

 

 

 

W, W1, H

W

Heat

Y, Y1, M

Y

Cooling

G, F

G

Fan

 

 

 

O

Do not continue

Changeover in cool (O terminal) or changeover in heat (B terminal).

 

installation

You have a single stage heat pump or zoning system. See page 2 for an

B

 

alternate thermostat model.

 

 

 

 

 

C, X, B

Do not connect

Transformer common.

 

 

 

W2, H2

Do not continue

Second stage heat (W2, H2) or second stage cooling (Y2).

 

installation.

You have a multistage heating/cooling system. See page 2 for an alternate

Y2

 

thermostat model.

 

 

 

 

 

*Remove factory-installed jumper between R and Rc terminals in 5-wire systems.

10 INSTALLATION

69-0654-5

Page 10
Image 10