Honeywell HCC-745NTW/PTW operation manual ① Mode User ② Control ③ RED Gain ④ Blue Gain Return

Models: HCC-745NTW/PTW

1 21
Download 21 pages 38.77 Kb
Page 14
Image 14

<< WB MODE >>

MODE

USER

CONTROL

R/B CONT

RED GAIN

1

BLUE GAIN

2

RETURN

 

<Fig5-6. White Balance Control>

5.7White Balance Mode

MODE

:To set how the camera tracks to accept different lighting conditions within the color range of 2,500°K ~ 8,000°K.

ATW (Auto Trace White Balance Mode)

:Feedback system that automatically aligns the white balance (2,500°K ~ 8,000°K).

IN (Indoor)

:General indoor scenes preset (3200°K)

OUT (Outdoor)

:Preset for outside environments and high contrast scenes where the camera is focused on the darker (5400°K)

MANUAL

:RED GAIN, BLUE GAIN are changed depending Black Body

AWC (Auto/PushAuto)

:Performs faster action than ATW mode without an operating range

FLUORES. (Fluorescent)

:Office environments with fluorescent or tungsten lighting. Provides lowest dynamic range of all presets (4200°K)

USER

: RED GAIN, BLUE GAIN are adjustable (0 ~ 255)

CONTROL

 

ATW

AUTO

IN

3200°K

OUT

5400°K

MANUAL

R<-->B

AWC

LOCK PUSH

AWC

AUTO

FLUORES.

4200°K

USER

R/B CONT

1.MANUAL : Press + or – button to adjust RED GAIN, BLUE GAIN automatically to fit Black Body.

2.PUSH : Press + or – button to start the AWC operation.

LoCK : Release the key to fit the present shooting scene’s white balance

RED GAIN (USER mode)

RED GAIN

0 1 …. 254 255

BLUE GAIN (USER mode)

BLUE GAIN

0 1 …. 254 255