Honeywell N7003V3 manual To Add a User, Security Codes & Authority Levels cont’d

Models: N7003V3

1 56
Download 56 pages 49 Kb
Page 17
Image 17
To Add a User

Security Codes & Authority Levels (cont’d)

To Add a User

IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones).

CODE

1. Enter Master or Manager code and press the

8

key.

2.Enter the new user’s 2-digit User Number (01-69).

3.Enter 4-digit security code for that user. The following prompts will appear.

ADD NEW USER? 0 = NO , 1 = YES

USER NUMBER = 03

ENTER AUTH. LEVEL

Enter 1 to add a new user code. Entering 0 will change the existing user’s code to the code entered in step 3. See Changing A User’s Code section.

Enter the authority level, 1-6, for this user within this partition.

1=master

2=manager

3=operator A

4=operator B

5=operator C

6=duress code

RF BUTTON ?

0 = NO , 1 = YES

This prompt will appear if a 5800 series button transmitter has been supplied and has not yet been assigned to a user. Press 1 if a button transmitter will be assigned to this user. Otherwise press 0.

ENTER BUTTON ZN # (01-64)

MULTI-ACCESS ? 0 = NO , 1 = YES

If assigning a button transmitter, this prompt will appear. Enter the button’s zone number (see your installer for zone number).

If you as a user have access to the other partition, the keypad will prompt for ability of this new user to access (GOTO) those partitions. Press 0 (NO) or 1 (YES). If no, the system activates this user code and exits “Add a User” mode. If yes, the keypad prompts for the Global Arm option for this user.

GLOBAL ARM ? 0 = NO , 1 = YES

Press 1 (YES) if this user will be allowed to try to arm more than one partition at the same time. Press 0 if this user will arm only his assigned partition.

– 17 –

Page 17
Image 17
Honeywell N7003V3 manual To Add a User, Security Codes & Authority Levels cont’d