Honeywell RTH8580WF manual System setup, 0190, 0240, 0250, Function, Settings & Options, 0180

Models: RTH8580WF

1 72
Download 72 pages 54.79 Kb
Page 57
Image 57
0180

System setup

How do I customize my heating/cooling system? (See page 51 for instructions.)

Function

Settings & Options

Note: Depending on system settings, functions on this page might not appear.

0180

Heating Fan

0

Gas or oil heat: Use this setting if you have a gas or oil heating system

 

Control

 

(system controls fan operation).

 

 

1

Electric heat: Use this setting if you have an electric heating system

 

 

 

(thermostat controls fan operation).

 

 

 

 

0190

Heat Pump

0

Cooling changeover valve: Use this setting if you connected a wire

 

Changeover Valve

 

labeled “O” to the O/B terminal.

 

(for heat pumps

1

Heating changeover valve: Use this setting if you connected a wire

 

only)

 

labeled “B” to the O/B terminal.

 

 

 

 

0240

Heating Cycle

5

Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).

 

Rate

9

Electric furnace: Electric heating systems.

0250

Heating Cycle

3

Hot water or high-efficiency furnace: Hot water system or gas furnace

 

(more than 90% efficiency).

 

Rate Stage 2

1

Gas/oil steam or gravity system: Steam or gravity heat systems.

 

 

 

 

55