System setup
How do I customize my heating/cooling system? (See page 51 for instructions.)
Function | Settings & Options |
Note: Depending on system settings, functions on this page might not appear.
0180 | Heating Fan | 0 | Gas or oil heat: Use this setting if you have a gas or oil heating system |
| Control |
| (system controls fan operation). |
|
| 1 | Electric heat: Use this setting if you have an electric heating system |
|
|
| (thermostat controls fan operation). |
|
|
|
|
0190 | Heat Pump | 0 | Cooling changeover valve: Use this setting if you connected a wire |
| Changeover Valve |
| labeled “O” to the O/B terminal. |
| (for heat pumps | 1 | Heating changeover valve: Use this setting if you connected a wire |
| only) |
| labeled “B” to the O/B terminal. |
|
|
|
|
0240 | Heating Cycle | 5 | Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency). |
| Rate | 9 | Electric furnace: Electric heating systems. |
0250 | Heating Cycle | 3 | Hot water or |
| (more than 90% efficiency). | ||
| Rate Stage 2 | 1 | Gas/oil steam or gravity system: Steam or gravity heat systems. |
|
|
|
|
55