Honeywell RTH8580WF Troubleshooting, Display is, blank, Cannot change, system setting, to Cool

Models: RTH8580WF

1 72
Download 72 pages 54.79 Kb
Page 64
Image 64

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

Display is

Check circuit breaker and reset if necessary.

blank

Make sure power switch at heating and cooling system is on.

 

Make sure furnace door is closed securely.

 

• Make sure C wire is connected (see page 15).

Cannot change

• Check Function 0170: System Type to make sure it is set to match your

system setting

 

heating and cooling equipment (see page 54).

to Cool

 

 

Fan does

• Check Function 0180: Heating Fan Control to make sure it is set to

not turn on

 

match your heating equipment (see page 55).

when heat is

 

 

required

 

 

“Wait” appears

Compressor protection feature is engaged. Wait 5 minutes for the system

on the screen

 

to restart safely, without damage to the compressor.

62

Page 64
Image 64
Honeywell RTH8580WF Troubleshooting, Display is, blank, Cannot change, system setting, to Cool, Fan does, not turn on