9. TROUBLESHOOTING

9. TROUBLESHOOTING

9-1. Check before and after troubleshooting

WARNING

Hazardous voltage can cause ELECTRIC SHOCK or DEATH. Disconnect power or turn off circuit breaker before you start checking or servicing.

9-1-1. Check power supply wiring.

Check that power supply wires are correctly connected to terminals No. 7 (L1) and No. 8 (L2) on the terminal plate in the outdoor unit.

Indoor

Inter–unit

Outdoor

 

 

unit

 

 

unit

power wiring

 

 

 

 

 

 

1

 

1

 

 

2

 

2

 

 

3

 

3

 

 

4

 

4

 

 

5

 

5

 

 

6

 

6

L1

Power supply :

 

 

7

Single- phase, 60Hz

 

 

L2

 

Inter–unit

8

115V.....CH0951,CH1251

 

 

230/208V............CH1852

 

control wiring

 

 

 

 

 

 

G

Ground

G G

 

Ground

 

 

 

 

 

 

 

9-1-2. Check inter-unit wiring.

Check that inter-unit wiring is correctly connected to the indoor unit from the outdoor unit.

9-1-3. Check power supply.

Check that voltage is in specified range (±10% of the rating).

Check that power is being supplied.

9-1-4. Check lead wires and connectors in indoor and outdoor units.

Check that coating of lead wires is not damaged.

Check that lead wires and connectors are firmly connected.

Check that wiring is correct.