9. TROUBLESHOOTING
9-1. Check before and after troubleshooting
WARNING
Hazardous voltage can cause ELECTRIC SHOCK or DEATH. Disconnect power or turn off circuit breaker before you start checking or servicing.
9-1-1. Check power supply wiring.
●Check that power supply wires are correctly connected to terminals No. 7 (L1) and No. 8 (L2) on the terminal plate in the outdoor unit.
Indoor | Outdoor |
|
| |
unit |
|
| ||
unit | power wiring |
|
| |
|
|
|
| |
1 |
| 1 |
|
|
2 |
| 2 |
|
|
3 |
| 3 |
|
|
4 |
| 4 |
|
|
5 |
| 5 |
|
|
6 |
| 6 | L1 | Power supply : |
|
| 7 | Single- phase, 60Hz | |
|
| L2 | ||
| 8 | 115V.....CH0951,CH1251 | ||
|
| 230/208V............CH1852 | ||
| control wiring |
|
| |
|
|
|
| |
G | Ground | G G |
| Ground |
|
|
| ||
|
|
|
|
9-1-2. Check inter-unit wiring.
●Check that
9-1-3. Check power supply.
●Check that voltage is in specified range (±10% of the rating).
●Check that power is being supplied.
●Check that coating of lead wires is not damaged.
●Check that lead wires and connectors are firmly connected.
●Check that wiring is correct.
54