10-2. Checking Continuity of Fuse on PCB Ass'y

10-2. Checking Continuity of Fuse on PCB Ass'y

Remove the PCB Ass’y from the electrical compo- nent box. Then pull out the fuse from the PCB Ass’y. (Fig. 5)

Check for continuity using a multimeter as shown in Fig. 6.

Fuse

PCB Ass’y

Fig. 5

10-3. Checking Motor Capacitor

Remove the lead wires from the capacitor terminals, and then place a probe on the capacitor terminals as shown in Fig. 7. Observe the deflection of the pointer, setting the resistance measuring range of the multime- ter to the maximum value.

The capacitor is “good” if the pointer bounces to a great extent and then gradually returns to its original position.

The range of deflection and deflection time differ according to the capacity of the capacitor.

Fuse

Fig. 6

Multimeter

Compressor motor capacitor

Fan motor

Fig. 7

capacitor