Sanyo CH0952, CH1852, KHS1852-S service manual Outdoor Unit, CH0951, CH1251

Models: KHS1852-S CH0952 CH1852

1 98
Download 98 pages 12.98 Kb
Page 16
Image 16
2-3-2. Outdoor Unit

2-3-2. Outdoor Unit

(1) Outdoor Unit

CH0951

PTC Thermistor

 

 

Resistance

Ω

at 77°F (25°C)

PS2A E20-470

47 ± 25%

Power Relay (PR)

 

 

Coil rating

 

 

Coil resistance

Ω

at 68°F (20°C)

Contact rating

 

 

DFU24D1-F

DC 24V

650 ± 10%

AC 250V, 20A

Thermostat (Defrost thermo. 23D)

Operating temp.

°F (°C)

TRS02-12MSR

ON

54 ± 4°F (12 ± 2°C)

Diff.

14 deg (8 deg). below

Thermostat (Low temp. cutoff 23A)

Operating temp.

°F (°C)

TRS02-M13MSR436

OFF (OPEN) : 5°F (–15°C)

ON (CLOSE) : 17°F (–8.3°C)

4-way Valve (Solenoid coil)

Coil rating

LB69001 (Coil), VH79102 (Valve)

AC 120V, 6W

DATA SUBJECT TO CHANGE WITHOUT NOTICE

(2) Outdoor Unit

CH1251

PTC Thermistor

 

 

Resistance

Ω

at 77°F (25°C)

PS2A E20-470

47 ± 25%

Power Relay (PR)

 

 

Coil rating

 

 

Coil resistance

Ω

at 68°F (20°C)

Contact rating

 

 

DFU24D1-F

DC 24V

650 ± 10%

AC 250V, 20A

Thermostat (Defrost thermo. 23D)

Operating temp.

°F (°C)

TRS02-12MSR

ON

54 ± 4°F (12 ± 2°C)

Diff.

14 deg (8 deg). below

Thermostat (Low temp. cutoff 23A)

Operating temp.

°F (°C)

TRS02-M13MSR436

OFF (OPEN) : 5°F (–15°C)

ON (CLOSE) : 17°F (–8.3°C)

4-way Valve (Solenoid coil)

Coil rating

LB69001 (Coil), V26-9201 (Valve)

AC 120V, 6W

DATA SUBJECT TO CHANGE WITHOUT NOTICE

12

Page 16
Image 16
Sanyo CH0952, CH1852, KHS1852-S service manual Outdoor Unit, CH0951, CH1251