Sanyo KHS1852-S Indoor unit KHS1852 Outdoor unit CH1852, Voltage Rating, Performance, Features

Models: KHS1852-S CH0952 CH1852

1 98
Download 98 pages 12.98 Kb
Page 8
Image 8
(3) Indoor unit KHS1852

(3) Indoor unit KHS1852

Outdoor unit CH1852

Voltage Rating

Cooling

Heating

 

230 / 208V 60Hz

Performance

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

BTU/h

 

17,000 / 16,500

 

19,000 / 18,500

 

 

 

 

kW

 

4.98 / 4.84

 

5.75 / 5.42

 

 

 

 

 

 

 

 

 

Air circulation (High)

 

ft3/min (m3/min)

 

 

390 (11.1)

 

Moisture removal (High)

 

 

Pints/h

 

4.5 / 4.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

V

 

 

187 – 253

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

 

7.6 / 8.1

 

7.1 / 7.5

 

 

 

 

 

 

 

 

 

 

Power input

 

 

W

 

1,700 / 1,660

 

1,610 / 1,540

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

%

 

99

 

99

 

 

 

 

 

 

 

 

 

 

SEER (HSPF)

 

 

BTU/W

 

10.5

 

(6.8)

 

 

 

 

 

 

 

 

 

Compressor locked rotor amperes

 

A

 

 

43

 

 

 

 

 

 

 

 

 

Heater element

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls / Temperature control

 

 

 

Microprocessor / I.C. thermostat

 

 

 

 

 

 

 

 

 

Control unit

 

 

 

 

Wireless remote control unit

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

ON / OFF 12 hours, 1-hour OFF

 

 

 

 

 

 

 

 

Fan speeds

Indoor / Outdoor

 

 

3 and Auto / 1 (Hi)

 

 

 

 

 

 

 

 

Airflow direction (Indoor)

Horizontal

 

 

Manual

 

 

 

 

Vertical

 

 

Auto

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

Washable

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

 

Refrigerant / Amount charged at shipment

lb. (kg)

 

 

3.97 (1.80)

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

Operation sound

Indoor: Hi / Me / Lo dB-A

 

 

41 / 38 / 36

 

 

Outdoor: Hi

 

dB-A

 

 

52

 

 

 

 

 

 

 

 

 

Refrigerant tubing connections

 

 

 

 

Flare

 

 

 

 

 

 

 

 

Max allowable tubing length at shipment

ft. (m)

 

 

25 (7.5)

 

 

 

 

 

 

 

 

 

Refrigerant tubing

Narrow tube

inch (mm)

 

 

1/4 (6.35)

 

diameter

Wide tube

 

inch (mm)

 

 

5/8 (15.88)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

 

inch (mm)

 

11-7/32 (285)

 

24-19/32 (625)

 

 

Width

 

inch (mm)

 

39-3/16 (995)

 

34-21/32 (880)

 

 

Depth

 

inch (mm)

 

7-23/32 (196)

 

12-19/32 (320)

 

 

 

 

 

 

 

 

 

 

Package dimensions

Height

 

inch (mm)

 

10-7/8 (276)

 

27-15/16 (710)

 

 

Width

 

inch (mm)

 

42-1/8 (1,070)

 

40-9/16 (1,030)

 

 

Depth

 

inch (mm)

 

14-9/32 (363)

 

16-3/16 (411)

 

 

 

 

 

 

 

 

 

 

Weight

Net

 

lb. (kg)

 

26.5 (12.0)

 

108 (49)

 

 

Shipping

 

lb. (kg)

 

33 (15.0)

 

117 (53)

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

 

cu.ft (m3)

 

3.78 (0.107)

 

10.6 (0.301)

Remarks: Rating conditions are

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

80°F D.B. / 67°F W.B.

 

 

 

 

Outdoor air temperature

95°F D.B. / 75°F W.B.

 

 

 

 

Heating: Indoor air temperature

70°F D.B.

 

 

 

 

Outdoor air temperature

47°F D.B. / 43°F W.B.

 

 

 

4

Page 8
Image 8
Sanyo KHS1852-S, CH0952 Indoor unit KHS1852 Outdoor unit CH1852, Voltage Rating, Performance, Electrical Rating, Features