6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit | KHS0951 |
|
|
|
|
| |||
Outdoor Unit | CH0951 |
|
|
|
|
|
| ||
| COOLING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Indoor Unit | Outdoor Unit | Complete Unit | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fan Motor | Fan Motor | Compressor |
|
|
|
|
|
|
|
|
|
| |
| Performance at |
|
|
| 115V Single | phase 60Hz |
| ||
|
|
|
|
|
|
|
|
| |
| Rating Conditions | Running Amps. | A | 0.40 | 0.70 | 7.4 | 8.5 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power Input | kW | 0.034 | 0.081 | 0.775 | 0.89 |
|
|
|
|
|
|
| |||
| Full Load Conditions Running Amps. | A | 0.40 | 0.70 | 9.1 | 10.2 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power Input | kW | 0.034 | 0.081 | 0.985 | 1.10 |
|
|
|
|
|
|
|
| ||
| Rating Conditions | : Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. |
| ||||||
|
|
|
| Outdoor Air Temperature 95°F (35°C) D.B. |
|
| |||
| Full Load Conditions : Indoor Air Temperature 95°F (35°C) D.B. / 70°F(21.2°C) W.B. |
| |||||||
|
|
|
| Outdoor Air Temperature 115°F (46.1°C) D.B. |
|
| |||
| HEATING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Indoor Unit | Outdoor Unit | Complete Unit | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fan Motor | Fan Motor | Compressor |
|
|
|
|
|
|
|
|
| ||
| Performance at |
|
|
| 115V Single | phase 60Hz |
| ||
|
|
|
|
|
|
|
|
| |
| Rating Conditions | Running Amps. | A | 0.40 | 0.70 | 7.3 | 8.4 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power Input | kW | 0.034 | 0.081 | 0.775 | 0.89 |
|
|
|
|
|
|
| |||
| Full Load Conditions Running Amps. | A | 0.40 | 0.70 | 8.6 | 9.7 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power Input | kW | 0.034 | 0.081 | 0.935 | 1.05 |
|
|
|
|
|
|
|
| ||
| Rating Conditions | : Indoor Air Temperature 70°F (21.1°C) D.B. |
|
| |||||
|
|
|
| Outdoor Air Temperature 47°F (8.3°C) D.B. / 43°F (6.1°C)W.B. |
| ||||
| Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B. |
|
| ||||||
|
|
|
| Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C)W.B. |
|