Sanyo CH1852, CH0952, KHS1852-S service manual Major Component Specifications, Indoor Unit

Models: KHS1852-S CH0952 CH1852

1 98
Download 98 pages 12.98 Kb
Page 9
Image 9
2-2. Major Component Specifications

2-2. Major Component Specifications

2-2-1. Indoor Unit

(1) Indoor unit KHS0951

Control PCB

Part No.

Controls

Control circuit fuse

POW-KHS095A, POW-KHS095B

Microprocessor

AC 115V – 3A

Remote Control Unit

 

 

RCS-1HS2U

 

 

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Cross-flow

 

 

 

 

 

Q’ty … Dia. and length

inch (mm)

1 … ø 3-3/4 / L24-9/32 (ø 95 / L617)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

KFV4-21H1PA … 1P

 

 

 

 

 

 

 

Nominal output

 

W

 

20

 

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

BLU

– BRN: 100.9

 

 

 

 

BLU

– PNK: 127.5

 

 

 

 

 

 

 

Run capacitor

 

µF

 

3.5

 

 

 

VAC

 

180

 

 

 

 

 

 

 

 

 

 

 

 

Flap Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Stepping motor

 

 

 

 

 

 

Model

 

 

MP24GA1

 

 

 

 

 

 

 

Rating

 

 

 

DC12V

 

 

 

 

 

Coil resistance (ambient temp. 77°F (25°C))

Ω

WHT – BLU (respectively 4 wires): 380 ± 7%

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

 

Rows

 

 

 

2

 

 

 

 

 

 

Fin pitch

inch (mm)

 

1/16 (1.4)

 

 

 

 

 

 

Face area

 

ft2 (m2)

1.40 (0.130)

DATA SUBJECT TO CHANGE WITHOUT NOTICE.