(2) Indoor unit | KHS1251 |
|
|
|
|
|
|
| |
Outdoor unit | CH1251 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling |
| Heating |
|
|
|
|
|
|
|
|
| |
Voltage Rating |
|
|
|
|
|
| 115V 60Hz | ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Performance |
|
|
|
|
| Cooling |
| Heating | |
|
|
|
|
|
|
|
|
|
|
| Capacity |
|
|
| BTU/h |
| 11,700 |
| 12,500 |
|
|
|
|
| kW |
| 3.43 |
| 3.66 |
|
|
|
|
|
|
|
| ||
| Air circulation (High) |
| ft3/min (m3/min) |
|
| 330 (9.35) | |||
| Moisture removal (High) |
|
| Pints/h |
| 3.4 |
| — | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Electrical Rating |
|
|
|
|
| Cooling |
| Heating | |
|
|
|
|
|
|
|
|
| |
| Available voltage range |
|
| V |
|
| 103 – 126 | ||
|
|
|
|
|
|
|
| ||
| Running amperes |
|
| A |
| 10.5 |
| 10.3 | |
|
|
|
|
|
|
|
|
| |
| Power input |
|
| W |
| 1,200 |
| 1,170 | |
|
|
|
|
|
|
|
|
| |
| Power factor |
|
| % |
| 99 |
| 99 | |
|
|
|
|
|
|
|
|
| |
| SEER (HSPF) |
|
| BTU/W |
| 10.2 |
| (6.8) | |
|
|
|
|
|
|
|
| ||
| Compressor locked rotor amperes |
| A |
|
| 60 | |||
|
|
|
|
|
|
|
| ||
| Heater element |
|
| kW |
|
| — | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |||
| Controls / Temperature control |
|
|
| Microprocessor / I.C. thermostat | ||||
|
|
|
|
|
|
|
| ||
| Control unit |
|
|
|
| Wireless remote control unit | |||
|
|
|
|
|
|
|
|
| |
| Timer |
|
|
|
|
| ON / OFF 12 hours, | ||
|
|
|
|
|
|
| |||
| Fan speeds | Indoor / Outdoor |
|
| 3 and Auto / 1 (Hi) | ||||
|
|
|
|
|
|
| |||
| Airflow direction (Indoor) | Horizontal |
|
| Manual | ||||
|
|
|
|
| Vertical |
|
| Auto | |
|
|
|
|
|
|
|
|
|
|
| Air filter |
|
|
|
|
|
| Washable | |
|
|
|
|
|
|
|
| ||
| Compressor |
|
|
|
| Rotary (Hermetic) | |||
|
|
|
|
|
|
| |||
| Refrigerant / Amount charged at shipment | lb. (kg) |
|
| 2.76 (1.25) | ||||
|
|
|
|
|
|
|
|
| |
| Refrigerant control |
|
|
|
|
| Capillary tube | ||
|
|
|
|
|
|
| |||
| Operation sound | Indoor: Hi / Me / Lo |
|
| 41 / 38 / 34 | ||||
|
|
| Outdoor: Hi |
|
|
| 48 | ||
|
|
|
|
|
|
|
| ||
| Refrigerant tubing connections |
|
|
|
| Flare | |||
|
|
|
|
|
|
| |||
| Max allowable tubing length at shipment | ft. (m) |
|
| 25 (7.5) | ||||
|
|
|
|
|
|
|
| ||
| Refrigerant tubing | Narrow tube | inch (mm) |
|
| 1/4 (6.35) | |||
| diameter |
| Wide tube |
| inch (mm) |
|
| 1/2 (12.7) | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
Dimensions & Weight |
|
|
|
| Indoor Unit |
| Outdoor Unit | ||
|
|
|
|
|
|
|
|
| |
| Unit dimensions | Height |
| inch (mm) |
|
| |||
|
|
| Width |
| inch (mm) |
|
| ||
|
|
| Depth |
| inch (mm) |
|
| ||
|
|
|
|
|
|
|
|
| |
| Package dimensions | Height |
| inch (mm) |
|
| |||
|
|
| Width |
| inch (mm) |
|
| ||
|
|
| Depth |
| inch (mm) |
|
| ||
|
|
|
|
|
|
|
|
|
|
| Weight |
| Net |
| lb. (kg) |
| 17.6 (8.0) |
| 83.8 (38) |
|
|
| Shipping |
| lb. (kg) |
| 22.0 (10.0) |
| 92.6 (42) |
|
|
|
|
|
|
|
|
| |
| Shipping volume |
|
| cu.ft (m3) |
| 2.51 (0.071) |
| 8.67 (0.246) | |
Remarks: Rating conditions are |
|
|
|
| DATA SUBJECT TO CHANGE WITHOUT NOTICE. | ||||
|
|
|
|
|
|
| |||
| Cooling: Indoor air temperature | 80°F D.B. / 67°F W.B. |
|
|
| ||||
|
| Outdoor air temperature | 95°F D.B. / 75°F W.B. |
|
|
| |||
| Heating: Indoor air temperature | 70°F D.B. |
|
|
| ||||
|
| Outdoor air temperature | 47°F D.B. / 43°F W.B. |
|
|
|