Sanyo CH0952 Indoor unit, KHS1251, Outdoor unit, CH1251, Voltage Rating, Performance, Features

Models: KHS1852-S CH0952 CH1852

1 98
Download 98 pages 12.98 Kb
Page 7
Image 7
(2) Indoor unit

(2) Indoor unit

KHS1251

 

 

 

 

 

 

 

Outdoor unit

CH1251

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

 

115V 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

 

BTU/h

 

11,700

 

12,500

 

 

 

 

 

kW

 

3.43

 

3.66

 

 

 

 

 

 

 

 

 

Air circulation (High)

 

ft3/min (m3/min)

 

 

330 (9.35)

 

Moisture removal (High)

 

 

Pints/h

 

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

V

 

 

103 – 126

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

 

10.5

 

10.3

 

 

 

 

 

 

 

 

 

 

Power input

 

 

W

 

1,200

 

1,170

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

%

 

99

 

99

 

 

 

 

 

 

 

 

 

 

SEER (HSPF)

 

 

BTU/W

 

10.2

 

(6.8)

 

 

 

 

 

 

 

 

 

Compressor locked rotor amperes

 

A

 

 

60

 

 

 

 

 

 

 

 

 

Heater element

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls / Temperature control

 

 

 

Microprocessor / I.C. thermostat

 

 

 

 

 

 

 

 

 

Control unit

 

 

 

 

Wireless remote control unit

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

 

ON / OFF 12 hours, 1-hour OFF

 

 

 

 

 

 

 

 

Fan speeds

Indoor / Outdoor

 

 

3 and Auto / 1 (Hi)

 

 

 

 

 

 

 

 

Airflow direction (Indoor)

Horizontal

 

 

Manual

 

 

 

 

 

Vertical

 

 

Auto

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

Washable

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

 

Refrigerant / Amount charged at shipment

lb. (kg)

 

 

2.76 (1.25)

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

Operation sound

Indoor: Hi / Me / Lo dB-A

 

 

41 / 38 / 34

 

 

 

Outdoor: Hi

 

dB-A

 

 

48

 

 

 

 

 

 

 

 

 

Refrigerant tubing connections

 

 

 

 

Flare

 

 

 

 

 

 

 

 

Max allowable tubing length at shipment

ft. (m)

 

 

25 (7.5)

 

 

 

 

 

 

 

 

 

Refrigerant tubing

Narrow tube

inch (mm)

 

 

1/4 (6.35)

 

diameter

 

Wide tube

 

inch (mm)

 

 

1/2 (12.7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

 

inch (mm)

 

10-5/8 (270)

 

21-1/4 (540)

 

 

 

Width

 

inch (mm)

 

31-11/16 (805)

 

31-1/2 (800)

 

 

 

Depth

 

inch (mm)

 

6-31/32 (177)

 

11-13/32 (290)

 

 

 

 

 

 

 

 

 

 

Package dimensions

Height

 

inch (mm)

 

9-13/16 (249)

 

23-31/32 (609)

 

 

 

Width

 

inch (mm)

 

33-21/32 (855)

 

38-5/8 (981)

 

 

 

Depth

 

inch (mm)

 

13-5/16 (338)

 

16-3/16 (411)

 

 

 

 

 

 

 

 

 

 

 

Weight

 

Net

 

lb. (kg)

 

17.6 (8.0)

 

83.8 (38)

 

 

 

Shipping

 

lb. (kg)

 

22.0 (10.0)

 

92.6 (42)

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

 

cu.ft (m3)

 

2.51 (0.071)

 

8.67 (0.246)

Remarks: Rating conditions are

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

80°F D.B. / 67°F W.B.

 

 

 

 

 

Outdoor air temperature

95°F D.B. / 75°F W.B.

 

 

 

 

Heating: Indoor air temperature

70°F D.B.

 

 

 

 

 

Outdoor air temperature

47°F D.B. / 43°F W.B.

 

 

 

3

Page 7
Image 7
Sanyo CH0952, CH1852 Indoor unit, KHS1251, Outdoor unit, CH1251, Voltage Rating, Performance, Electrical Rating, Features