CH0952, CH1852, KHS1852-S service manual Top view, Bottom view
Models:
KHS1852-S
CH0952
CH1852
1
43
98
98
Download
98 pages
12.98 Kb
40
41
42
43
44
45
46
47
<
>
Troubleshooting
Specs
Cooling Characteristics
Install
Refrigerant Flow Diagram
Dimension
Recommended Wire Length and Diameter
E. Check TIMER on the remote control unit
Adjusting the Fan Speed
115V Single phase 60 Hz
Page 43
Image 43
(7)
Printed circuit board
POW-KHS095B
(for KHS0951 and KHS1251)
Top view
Bottom view
39
Page 42
Page 44
Page 43
Image 43
Page 42
Page 44
Contents
KHS0951 KHS1251
KHS0951 / CH0951 KHS1251 / CH1251
KHS1852 / CH1852
KHS1852 CH1852
When Servicing
In Case of Improper Installation
When Installing…
When Connecting Refrigerant Tubing
Table of Contents
APPENDIX
CHECKING ELECTRICAL COMPONENTS
Outdoor Air Intake Temp
1. OPERATING RANGE
Temperature
Indoor Air Intake Temp
CH0951
2. SPECIFICATIONS
2-1.Unit Specifications
KHS0951
KHS1251
Features
Dimensions & Weight
2 Indoor unit
Voltage Rating
Features
Dimensions & Weight
3 Indoor unit KHS1852 Outdoor unit CH1852
2-2-1.Indoor Unit
2-2.Major Component Specifications
Fan & Fan Motor
Remote Control Unit
2 Indoor unit KHS1251
Control PCB
Fan & Fan Motor
Remote Control Unit
3 Indoor unit KHS1852
Control PCB
1 Outdoor unit CH0951
2-2-2.Outdoor Unit
Fan & Fan Motor
2 Outdoor unit CH1251
Control PCB
Compressor
Fan & Fan Motor
3 Outdoor unit CH1852
Control PCB
Compressor
KHS1251
2-3.Other Component Specifications
2-3-1.Indoor Unit
KHS0951
2 Outdoor Unit
2-3-2.Outdoor Unit
1 Outdoor Unit
CH0951
DFU24D1-F
Power Relay PR
3 Outdoor Unit
CH1852
1 Indoor unit KHS0951 / KHS1251
3. DIMENSIONAL DATA
3-1.Unit
3-1-1.Indoor Unit
2 Indoor unit KHS1852
1 Outdoor unit CH0951 / CH1251
3-1-2.Outdoor Unit
4-ø15/32
12-19/32 Narrow tube service valve ø6.35 1/4
Wide tube service valve ø15.88 5/8 Unit inch mm
2Outdoor unit CH1852
Outdoor unit CH0951 / CH1251
4. REFRIGERANT FLOW DIAGRAM
4-1.Refrigerant Flow Diagram
Indoor unit KHS0951 / KHS1251
Heating Characteristics
5-1.Performance Charts
5. PERFORMANCE DATA
Cooling Characteristics
CH1251
Cooling Characteristics
Heating Characteristics
KHS1251
CH1852
Cooling Characteristics
Heating Characteristics
KHS1852
High
5-2.Air Throw Distance Chart
Cooling Room air temp. 80¡F 26.7¡C
Fan speed
Horizontal distance ft
Cooling Room air temp. 80¡F 26.7¡C
Fan speed
High
Horizontal distance ft
Cooling Room air temp. 80¡F 26.7¡C
Fan speed
High
CH0951
5-3.Cooling Capacity
115V Single phase 60 Hz
KHS0951
TC Total Cooling Capacity
115 V Single phase 60 Hz
KHS1251
CH1251
TC Total Cooling Capacity
208 V Single phase 60 Hz
KHS1852
CH1852
TC Total Cooling Capacity
230 V Single phase 60 Hz
KHS1852
CH1852
5-4.Heating Capacity
Outdoor temperature ¡F DB
Heating capacity ratio %
CH0951
6-1.Electrical Characteristics
6. ELECTRICAL DATA
KHS0951
HEATING
KHS1251
CH1251
COOLING
HEATING
KHS1852
CH1852
COOLING
1 Indoor unit KHS0951 / KHS1251
6-2.Electric Wiring Diagrams
2 Indoor unit KHS1852
disconnect power before checking, servicing
and/or cleaning any electrical parts
To avoid electrical shock hazard, be sure to
3 Outdoor unit CH0951 / CH1251
disconnect power before checking, servicing
and/or cleaning any electrical parts
To avoid electrical shock hazard, be sure to
4 Outdoor unit CH1852
disconnect power before checking, servicing
and/or cleaning any electrical parts
To avoid electrical shock hazard, be sure to
Top view
5 Printed circuit board POW-KHS095Afor KHS0951
Bottom view
Top view
6 Printed circuit board POW-KHS125Afor KHS1251
Bottom view
Bottom view
Top view
Top view
8 Printed circuit board POW-KHS1852for KHS1852
Bottom view
Top view
AVOID
7. INSTALLATION INSTRUCTIONS
7-1.Installation Site Selection
7-1-1.Indoor Unit
Fig. 5a
7-1-2.Outdoor Unit
Install the outdoor unit above snowfall line
AVOID
Fig. Non-removablemounting
7-2.Remote Control Unit Installation Position
7-2-1.Mounting on a Wall
Removable mounting
Remote Control Unit
7-3.Address Switches
7-3-1.Finding the Address Switches
7-3-2.Switch Positions for Up to 2 Units
Each wire must be firmly connected
7-4.Recommended Wire Length and Diameter
WIRING SYSTEM DIAGRAM
8. FUNCTION
8-1.Room Temperature Control
Cooling
Heating
8-2.Dry Operation Dehumidification
8-5.Overload Prevention Heating
8-4.Freeze Prevention Cooling
8-6.Cold draft Prevention Heating
Defrosting Flowchart
8-7.Defrosting Operation Heating
Defrosting Mode Timing Chart
8-8.Low Temperature Cutff Heating
9-1-2.Check inter-unitwiring
9. TROUBLESHOOTING
9-1.Check before and after troubleshooting
9-1-1.Check power supply wiring
9-2-1.Circuit breaker trips or fuse blows
9-2.Air conditioner does not operate
A. Power is not supplied
9-2-2.Neither indoor nor outdoor unit runs
E. Check TIMER on the remote control unit
C. Check remote control unit
D. Check fuse on the indoor PCB Assy
9-2-4.Only indoor unit does not run
9-2-3.Only outdoor unit does not run
A. Check setting temperature
9-3-1.Only indoor fan does not run
9-3.Some part of air conditioner does not operate
9-3-2.Only flap motor does not run
9-3-5.Only compressor does not run
9-3-4.Only outdoor fan does not run
HEAT COOL
COOL HEAT
9-4-3.Excessive cooling or heating
9-4-2.Poor cooling or heating
B. Short
9-5.If a sensor is defective
9-5-2.Room temp. thermistor TH2 is defective
A. Open
10-1-2.Indoor Unit
10-1-1.Power Supply Wires
10. CHECKING ELECTRICAL COMPONENTS
10-1.Measurement of Insulation Resistance
10-3.Checking Motor Capacitor
10-2.Checking Continuity of Fuse on PCB Assy
Indoor Unit KHS0951 / KHS1251
11. ARRANGEMENT OF ELECTRICAL COMPONENT
KHS1852
Electric Parts
Outdoor Unit CH0951 / CH1251 / CH1852
Parts Layout in Unit
KHS0951 + CH0951 KHS1251 + CH1251
APPENDIX
KHS1852 + CH1852
Features
Alert Symbols
Contents
Product Information
Safety Instructions
Installation Location
Electrical Requirements
Drain hose Refrigerant tubes OUTDOOR UNIT
Names of Parts
Remote Control Unit
INDOOR UNIT Air intakes Air outlet
Unit Display and Operation Selector
H OFF
Remote Control Unit Display
Symbols
SET TEMP
Remote Control Unit
Remote Control Unit continued
Remote Control Unit Installation Position
Using the Remote Control Unit
How to Install Batteries
How to Use the Remote Control Unit
Mounting the Remote Control Unit
Using the Remote Control Unit continued
1. Automatic Operation
Operation with the Remote Control Unit
To lower the temperature setting
Operation with the Remote Control Unit continued
Press TEMP. to change the temperature setting
To raise the temperature TEMP. setting
2. Manual Operation
Operation with the Remote Control Unit continued
3.Adjusting the Fan Speed
Operation with the Remote Control Unit continued
BATTERIES ACL
Operation with the Remote Control Unit continued
4. Night Setback Mode
The Night Setback Mode is used for saving energy
A. In Cooling and DRY Mode and
Operation with the Remote Control Unit continued
``DRY Operation
Special Remarks
Power failure during operation Clicking Sound
Remote Control Unit
H OFF
Using the 12-HourON and OFF Timer
Using the 1-HourOFF Timer
1. Horizontal
Adjusting the Airflow Direction
2. Vertical
Care and Cleaning
Operation without the Remote Control Unit
Air intake grille
Care and Cleaning continued
Anti-moldfilter How to remove the anti-moldfilter
How to replace the anti-moldfilter
Air cleaning filter not provided
Care and Cleaning continued
Care and Cleaning continued
Tips for Energy Saving
Do not
Operating Range
Troubleshooting
SANYO FISHER SERVICE CORPORATION
For Parts or Service Contact
A DIVISION OF SANYO LOGISTICS CORPORATION