(2) Outdoor unit CH1251
Control PCB
Part No.
Controls
Control circuit fuse
—
—
Compressor |
|
|
| ||
|
|
|
|
|
|
| Type |
|
| Rotary (Hermetic) | |
|
|
|
|
|
|
| Compressor model |
|
| ||
|
|
|
|
|
|
| Nominal output |
| W | 950 | |
|
|
|
|
|
|
| Compressor oil … Amount |
| cc | SUNISO | |
|
|
|
|
| |
| Coil resistance (ambient temp. 68°F (20°C)) | Ω | C – R: 0.576 | ||
|
|
|
|
| C – S: 3.070 |
|
|
|
|
|
|
| Safety devices Type |
|
| External (OLR) | |
|
|
|
|
|
|
|
| Overload relay |
|
| |
|
|
|
|
| |
| Run capacitor |
| µF | 40 | |
|
|
|
| VAC | 400 |
|
|
|
|
| |
| Crank case heater |
|
| 115V, 20W | |
|
|
|
|
| |
|
|
|
| ||
Fan & Fan Motor |
|
|
| ||
|
|
|
|
| |
| Type |
|
| Propeller | |
|
|
|
| ||
| Q’ty … Dia. and length | inch. (mm) | 1 … | ||
|
|
|
|
| |
| Fan motor model … Q’ty |
|
| ||
|
|
|
|
| |
| No. of poles … rpm (115V, High) |
|
| 6 … 630 | |
|
|
|
|
| |
| Nominal output |
| W | 20 | |
|
|
|
| ||
| Coil resistance (ambient temp. 68°F (20°C)) | Ω | BLU – BRN: 45.3 | ||
|
|
|
|
| BLU – PNK: 50.5 |
|
|
|
|
| |
| Run capacitor |
| µF | 8 | |
|
|
|
| VAC | 220 |
|
|
|
|
| |
|
|
|
|
|
|
Heat Exchanger Coil |
|
|
| ||
|
|
|
|
| |
| Coil |
|
| Aluminum plate fin / Copper tube | |
|
|
|
|
| |
| Rows |
|
| 2 | |
|
|
|
| ||
| Fin pitch | inch (mm) | 1/16 (1.4) | ||
|
|
|
|
| |
| Face area |
| ft2 (m2) | 3.37 (0.313) |
External Finish
Acrylic
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
9