Sanyo CH0952 Outdoor unit CH1251, Control PCB, Compressor, Fan & Fan Motor, Heat Exchanger Coil

Models: KHS1852-S CH0952 CH1852

1 98
Download 98 pages 12.98 Kb
Page 13
Image 13
(2) Outdoor unit CH1251

(2) Outdoor unit CH1251

Control PCB

Part No.

Controls

Control circuit fuse

POW-CH095

Compressor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

Compressor model

 

 

C-R95H2E

 

 

 

 

 

 

 

Nominal output

 

W

950

 

 

 

 

 

 

 

Compressor oil … Amount

 

cc

SUNISO 4GSD-T … 570

 

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

C – R: 0.576

 

 

 

 

 

C – S: 3.070

 

 

 

 

 

 

 

Safety devices Type

 

 

External (OLR)

 

 

 

 

 

 

 

 

Overload relay

 

 

MRA98693-9200

 

 

 

 

 

 

Run capacitor

 

µF

40

 

 

 

 

VAC

400

 

 

 

 

 

 

Crank case heater

 

 

115V, 20W

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

Type

 

 

Propeller

 

 

 

 

 

Q’ty … Dia. and length

inch. (mm)

1 … 16-17/32 (ø 420)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

UE6-21BA1PA … 1

 

 

 

 

 

 

No. of poles … rpm (115V, High)

 

 

6 … 630

 

 

 

 

 

 

Nominal output

 

W

20

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

BLU – BRN: 45.3

 

 

 

 

 

BLU – PNK: 50.5

 

 

 

 

 

 

Run capacitor

 

µF

8

 

 

 

 

VAC

220

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

Rows

 

 

2

 

 

 

 

 

Fin pitch

inch (mm)

1/16 (1.4)

 

 

 

 

 

 

Face area

 

ft2 (m2)

3.37 (0.313)

External Finish

Acrylic baked-on enamel finish

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

9

Page 13
Image 13
Sanyo CH0952, CH1852 Outdoor unit CH1251, Control PCB, Compressor, Fan & Fan Motor, Heat Exchanger Coil, External Finish