14 - 1

14. COMMUNICATION FUNCTIONS
14. COMMUNICATION FUNCTIONS

This servo amplifier has the RS-422 and RS-232C serial communication functions. These functions can be

used to perform servo operation, parameter changing, monitor function, etc.

However, the RS-422 and RS-232C communication functions cannot be used together. Select between RS-

422 and RS-232C with parameter No.16. (Re fer to Section 14.2.2.)

14.1 Configuration

14.1.1 RS-422 configuration

(1) Outline

Up to 32 axes of servo amplifiers from stations 0 to 31 can be operated on the same bus.

CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
RS-422
Controller such as
personal computer
RS-232C/
RS-422
converter
To CN3
Axis 1 (Station 0) Axis 2 (Station 1) Axis 32 (Station 31)
Unavailable as option.
To be prepared by customer.
To CN3 To CN3
Servo amplifier Servo amplifier Servo amplifier

(2) Cable connection diagram

Wire as shown below:

RDP
RDN
SDP
SDN
GND
GND
5
15
9
19
11
1
10
RDP
RDN
SDP
SDN
LG
LG
TRE
SD
5
15
9
19
11
1
10
RDP
RDN
SDP
SDN
LG
LG
TRE
SD
5
15
9
19
11
1
10
RDP
RDN
SDP
SDN
LG
LG
TRE
SD
(Note 3) 30m max.
Plate
(Note 1)
Axis 2 servo amplifier
CN3 connector
Plate Plate
(Note 2)
RS-422
output unit
(Note 1)
Axis 1 servo amplifier
CN3 connector
(Note 1)
Axis 32 (last axis)
servo amplifier
CN3 connector

Note: 1. Connector set MR-J2CN1(3M or equivalent)

Connector: 10120-3000VE

Shell kit: 10320-52F0-008

2. In the last axis, connect TRE and RDN.

3. 30m max. in environment of little noise.