5. PARAMETERS

Class No. Symbol

50

51 *OP6

52

53 *OP8

parameters 2

54 *OP9

Expansion

 

 

 

 

 

Name and function

Initial

Unit

Setting

Control

 

 

 

 

value

range

mode

 

 

 

 

 

 

For manufacturer setting

0000

 

 

 

Must not be changed.

 

 

 

 

Function selection 6

0000

 

0000h

P S T

Used to select the operation to be performed when the alarm reset

 

 

to

 

signal switches on.

 

 

0100h

 

0

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation to be performed when the alarm reset signal switches on

0:Base circuit not switched off

1:Base circuit switched off

For manufacturer setting

0000

 

 

Must not be changed.

 

 

 

Function selection 8

0000

0000h

P S T

Used to select the protocol of serial communication.

 

to

 

0

 

 

0

 

0110h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protocol checksum selection

0:Yes (checksum added)

1:No (checksum not added)

Protocol checksum selection

0:With station numbers

1:No station numbers

Function selection 9

0000

0000h

P S T

Use to select the command pulse rotation direction, encoder output

 

to

 

pulse direction and encoder pulse output setting.

 

1101h

 

0

Servo motor rotation direction changing Changes the servo motor rotation direction for the input pulse train.

 

Servo motor rotation direction

Set value

At forward rotation

At reverse rotation

 

pulse input (Note)

pulse input (Note)

 

 

 

0

CCW

CW

1

CW

CCW

 

 

 

Note. Refer to Section 3.4.1, (1), (a).

Encoder output pulse phase changing

Changes the phases of A, B-phase encoder output pulses.

Set value

Servo motor rotation direction

CCW

CW

 

0

A phase

A phase

B phase

B phase

 

1

A phase

A phase

B phase

B phase

 

Encoder pulse output setting selection (refer to parameter No. 27)

0:Output pulse setting

1:Division ratio setting

5 - 20

Page 117
Image 117
Mitsubishi Electronics MR-J2S- A instruction manual 51 *OP6 53 *OP8 Parameters 54 *OP9 Expansion