13. OPTIONS AND AUXILIARY EQUIPMENT

13.1.3 Junction terminal block (MR-TB20)

POINT

When using the junction terminal block, you cannot use SG of CN1A-20 and CN1B-20. Use SG of CN1A-4 and CN1B-4.

(1)How to use the junction terminal block

Always use the junction terminal block (MR-TB20) with the junction terminal block cable (MR- J2TBL05M) as a set. A connection example is shown below:

Servo amplifier

Junction terminal block

Cable clamp MR-TB20(AERSBAN-ESET)

CN1A or

CN1B Junction terminal block cable

(MR-J2TBL05M)

Ground the junction terminal block cable on the junction terminal block side with the standard accessory cable clamp fitting (AERSBAN-ESET). For the use of the cable clamp fitting, refer to Section 13.2.6, (2).

(2)Terminal labels

Among the terminal block labels for the junction terminal block, use the two for the MR-J2S-A(MR-J2- A). When changing the input signals in parameters No. 43 to 48, refer to (4) in this section and Section 3.3 and apply the accessory signal seals to the labels.

1) For CN1A

2) For CN1B

LG

PP

LZ

 

LB

COM

OPC

PG

LZR

LBR

RD

 

 

LG

VDD

SON

 

10

 

11

 

12

 

 

13

 

14

 

15

 

16

 

17

 

18

 

19

 

 

10

 

11

 

12

 

13

 

NP

P15R

 

LA

CR

SG

NG

OP

LAR

INP

SD

 

 

VC

DO1

TLC

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

 

 

0

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TL

P15R

COM

EMG

LSN

ZSP

 

 

14

 

15

 

16

 

17

 

18

 

19

 

 

PC

SG

TLA

RES

LSP

ALM

SD

3

 

4

 

5

 

6

 

7

 

8

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3) Outline drawing

126(4.96)

 

[Unit: mm]

 

([Unit: in.])

 

 

117(4.61)

 

 

MITSUBISHI

50(1.97)

60(2.36)

MR-TB20

 

 

 

2- 4.5(0.18)

 

46.2(1.82)

7

(0.28)

Terminal screw: M3.5

Applicable cable: Max. 2mm2

(Crimping terminal width: 7.2mm (0.283 in) max.)

13 - 13

Page 206
Image 206
Mitsubishi Electronics MR-J2S- A Junction terminal block MR-TB20, How to use the junction terminal block, Terminal labels