6.DISPLAY AND OPERATION

6.DISPLAY AND OPERATION

6.1 Display flowchart

Use the display (5-digit, 7-segment LED) on the front panel of the servo amplifier for status display, parameter setting, etc. Set the parameters before operation, diagnose an alarm, confirm external sequences, and/or confirm the operation status. Press the "MODE" "UP" or "DOWN" button once to move to the next screen.

To refer to or set the expansion parameters, make them valid with parameter No. 19 (parameter write disable).

Status display

Diagnosis

(Note)

 

Cumulative feedback

Sequence

pulses [pulse]

 

button

 

MODE

Expansion

Expansion

Alarm

Basic

parameters

parameters 1

parameters 2

 

Current alarm

Parameter No. 0

Parameter No. 20

Parameter No. 50

Motor speed [r/min]

Droop pulses [pulse]

Cumulative command pulses [pulse]

Command pulse frequency [kpps]

Speed command voltage Speed limit voltage[mV]

Torque limit voltage Torque command voltage

[mV]

Regenerative load ratio [%]

Effective load ratio [%]

Peak load ratio [%]

Instantaneous torque [%]

Within one-revolution position low [pulse]

Within one-revolution position, high [100 pulses]

ABS counter [rev]

Load inertia moment ratio [times]

External I/O signal display

Output signal forced output

Test operation

Jog feed

Test operation Positioning operation

Test operation Motor-less operation

Test operation

Machine analyzer operation

Software version L

Software version H

Automatic VC offset

Motor series ID

Motor type ID

Encoder ID

Last alarm

Parameter No. 1

Parameter No. 21

Parameter No. 51

Second alarm in past

UP

Third alarm in past

DOWN

Fourth alarm in past

Parameter No. 18

Parameter No. 48

Parameter No. 83

Fifth alarm in past

Parameter No. 19

Parameter No. 49

Parameter No. 84

Sixth alarm in past

Parameter error No.

Bus voltage [V]

Note: The initial status display at power-on depends on the control mode.

Position control mode: Cumulative feedback pulses(C), Speed control mode: Motor speed(r),

Torque control mode: Torque command voltage(U)

Also, parameter No. 18 can be used to change the initial indication of the status display at power-on.