6. DISPLAY AND OPERATION

6.5 Parameter mode

The parameters whose abbreviations are marked are made valid by changing the setting and then switching power off once and switching it on again. Refer to Section 5.1.2.

(1)Operation example

The following example shows the operation procedure performed after power-on to change the control mode (parameter No. 0) to the speed control mode.

Using the "MODE" button, show the basic parameter screen.

The parameter number is displayed.

Press UP orDOWN to change the number.

Press SET twice.

The set value of the specified parameter number flickers.

Press UP once.

During flickering, the set value can be changed.

Use UP or DOWN .

(

2: Speed control mode)

Press SET to enter.

/

To shift to the next parameter, press the UP DOWN button.

When changing the parameter No. 0 setting, change its set value, then switch power off once and switch it on again to make the new value valid.

(2)Expansion parameters

To use the expansion parameters, change the setting of parameter No. 19 (parameter write disable). Refer to section 5.1.1.

6 - 8