COMPLIANCE WITH EC DIRECTIVES

1. WHAT ARE EC DIRECTIVES?

The EC directives were issued to standardize the regulations of the EU countries and ensure smooth distribution of safety-guaranteed products. In the EU countries, the machinery directive (effective in January, 1995), EMC directive (effective in January, 1996) and low voltage directive (effective in January, 1997) of the EC directives require that products to be sold should meet their fundamental safety requirements and carry the CE marks (CE marking). CE marking applies to machines and equipment into which servo amplifiers have been installed.

(1)EMC directive

The EMC directive applies not to the servo units alone but to servo-incorporated machines and equipment. This requires the EMC filters to be used with the servo-incorporated machines and equipment to comply with the EMC directive. For specific EMC directive conforming methods, refer to the EMC Installation Guidelines (IB(NA)67310).

This servo is certified by TUV, third-party assessment organization, to comply with the EMC directive in the conforming methods of the EMC Installation Guidelines.

(2)Low voltage directive

The low voltage directive applies also to servo units alone. Hence, they are designed to comply with the low voltage directive.

This servo is certified by TUV, third-party assessment organization, to comply with the low voltage directive.

(3)Machine directive

Not being machines, the servo amplifiers need not comply with this directive.

2.PRECAUTIONS FOR COMPLIANCE

(1) Servo amplifiers and servo motors used

Use the servo amplifiers and servo motors which comply with the standard model.

Servo amplifier series

:MR-J2S-10A(1) to MR-J2S-350A(1)

Servo motor series

:HC-KFS

 

HC-MFS

 

HC-SFS

 

HC-RFS

 

HC-UFS

(2) Configuration

 

 

 

 

Control box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reinforced

 

 

 

 

 

 

 

 

 

 

 

insulating type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reinforced

 

 

 

 

 

 

 

 

 

 

24VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

power

 

 

 

insulating

No-fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Magnetic

 

 

 

 

 

 

supply

 

 

 

transformer

 

 

 

 

 

 

 

 

 

Servo

breaker

 

 

contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

motor

 

 

 

 

 

 

 

 

 

 

 

 

Servo

 

 

 

 

 

 

 

NFB

 

 

MC

 

 

 

 

 

amplifier

 

 

SM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3)Environment

Operate the servo amplifier at or above the contamination level 2 set forth in IEC664. For this purpose, install the servo amplifier in a control box which is protected against water, oil, carbon, dust, dirt, etc. (IP54).

A - 7

Page 8
Image 8
Mitsubishi Electronics MR-J2S- A EMC directive, Low voltage directive, Machine directive, Configuration, Environment