3 - 56
3. SIGNALS AND WIRING
3.11 Servo amplifier terminal block (TE2) wiring m ethod
(1) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is. (Cable size: 0.2 to
2.5mm2)
Approx. 10mm
Twisted wire: Use the cable after stripping the sh eath and tw is ting th e core . A t this time , take c are to
avoid a short caused by the loose wires of the core and the adjacent pole. Do not solder
the core as it may cause a contact fault. (Cab le size: 0.2 to 2.5mm2)Alternatively, a bar
terminal may be used to put the wir es together.(Phoenix contact m ake)
Bar terminal for 1 cable
(Bar terminal ferrule with insulation sleeve)
Bar terminal for 2 cable
(Twin ferrule with insulation sleeve)
Cable size Bar terminal type
[mm2] AWG For 1 cable For 2 cables
Crimping
tool
0.25 24 Al0.25-6YE
Al0.25-8YE
0.5 20 Al0.5-6WH
Al0.5-8WH
0.75 18 Al0.75-6GY
Al0.75-8GY Al-TWIN2 0.75-8GY
Al-TWIN2 0.75-10GY
118
Al1-6RD
Al1-8RD Al-TWIN2 1-8RD
Al-TWIN2 1-10RD
1.5 16 Al1.5-6BK
Al1.5-8BK Al-TWIN2 1.5-8BK
Al-TWIN2 1.5-12BK
2.5 14 Al2.5-8BU
Al2.5-8BU-1000 Al-TWIN2 2.5-10BU
Al-TWIN2 2.5-13BU
CRIMPFOX-UD6