14. COMMUNICATION FUNCTIONS

14.12.5 Disable/enable of external I/O signals (DIO)

Inputs can be disabled independently of the external I/O signal ON/OFF. When inputs are disabled, the input signals are recognized as follows. Among the external input signals, EMG, LSP and LSN cannot be disabled.

Signal

Status

External input signals (DI)

OFF

External analog input signals

0V

Pulse train inputs

None

(1)Disabling/enabling the external input signals (DI), external analog input signals and pulse train inputs with the exception of EMG, LSP and LSN.

Transmit the following communication commands:

(a) Disable

 

Command

Data No.

Data

 

[9][0]

[0][0]

1EA5

(b) Enable

 

 

 

 

 

 

 

Command

Data No.

Data

 

[9][0]

[1][0]

1EA5

(2)Disabling/enabling the external output signals (DO) Transmit the following communication commands:

(a) Disable

 

Command

Data No.

Data

 

[9][0]

[0][3]

1EA5

(b) Enable

 

 

 

 

 

 

 

Command

Data No.

Data

 

[9][0]

[1][3]

1EA5