13. OPTIONS AND AUXILIARY EQUIPMENT

13.2.4 Relays

The following relays should be used with the interfaces:

Interface

Selection example

Relay used especially for switching on-off analog input

To prevent defective contacts , use a relay for small signal

command and input command (interface DI-1) signals

(twin contacts).

 

(Ex.) Omron : type G2A , MY

Relay used for digital output signals (interface DO-1)

Small relay with 12VDC or 24VDC of 40mA or less

 

(Ex.) Omron : type MY

13.2.5 Surge absorbers

A surge absorber is required for the electromagnetic brake. Use the following surge absorber or equivalent. Insulate the wiring as shown in the diagram.

 

 

Maximum rating

 

 

 

 

Static

 

Permissible circuit

 

Surge

Energy

Rated

Maximum

capacity

Varistor voltage

 

limit voltage

(reference

rating (range) V1mA

voltage

 

immunity

immunity

power

 

 

 

 

value)

 

 

 

 

 

 

 

 

 

 

 

 

AC[Vma]

 

DC[V]

 

[A]

[J]

[W]

[A]

 

[V]

[pF]

[V]

140

180

 

(Note)

5

0.4

25

 

360

300

220

 

500/time

 

(198 to 242)

 

 

 

 

 

 

 

 

 

 

Note: 1 time

 

8 20 s

(Example)

ERZV10D221 (Matsushita Electric)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TNR-12G221K (Marcon Electronics)

 

 

 

 

 

 

 

 

 

Outline drawing [mm] ( [in] ) (ERZ-C10DK221)

 

 

 

13.5 (0.53) 4.7 1.0 (0.190.04)

16.5

(0.65)

 

 

0.8 (0.03)

 

3.0(0.12)

orless

(1.18)30.0 moreor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vinyl tube

Crimping terminal for M4 screw

13.2.6 Noise reduction techniques

Noises are classified into external noises which enter the servo amplifier to cause it to malfunction and those radiated by the servo amplifier to cause peripheral devices to malfunction. Since the servo amplifier is an electronic device which handles small signals, the following general noise reduction techniques are required.

Also, the servo amplifier can be a source of noise as its outputs are chopped by high carrier frequencies. If peripheral devices malfunction due to noises produced by the servo amplifier, noise suppression measures must be taken. The measures will vary slightly with the routes of noise transmission.

(1)Noise reduction techniques

(a) General reduction techniques

Avoid laying power lines (input and output cables) and signal cables side by side or do not bundle them together. Separate power lines from signal cables.

Use shielded, twisted pair cables for connection with the encoder and for control signal transmission, and connect the shield to the SD terminal.

Ground the servo amplifier, servo motor, etc. together at one point (refer to Section 3.10).

13 - 22

Page 215
Image 215
Mitsubishi Electronics MR-J2S- A Relays, Following relays should be used with the interfaces, Surge absorbers, Dcv