3. SIGNALS AND WIRING

Note: 1. To prevent an electric shock, always connect the protective earth (PE) terminal of the (terminal marked ) servo amplifier to the protective earth (PE) of the control box.

2.Connect the diode in the correct direction. If it is connected reversely, the servo amplifier will be faulty and will not output signals, disabling the emergency stop and other protective circuits.

3.The emergency stop switch(normally closed contact) must be installed.

4.CN1A, CN1B, CN2 and CN3 have the same shape. Wrong connection of the connectors will lead to a fault.

5.The sum of currents that flow in the external relays should be 80mA max. If it exceeds 80mA, supply interface power from external. (Refer to Section 3.6.2)

6.Trouble (ALM) is connected with COM in normal alarm-free condition.

7.When connecting the personal computer together with monitor outputs 1, 2, use the maintenance junction card (MR-J2CN3TM).

8.The pins with the same signal name are connected in the servo amplifier.

9.Use MRZJW3-SETUP 121E.

10.When using the internal power supply (VDD), always connect VDD-COM. Do not connect them when supplying external power. Refer to Section 3.6.2.

11.Use an external power supply when inputting a negative voltage.

3 - 9

Page 42
Image 42
Mitsubishi Electronics MR-J2S- A instruction manual Signals and Wiring