5. PARAMETERS

Class No. Symbol

14 TQC

parametersBasic

15

*SNO

16

*BPS

 

Name and function

Initial

Unit

Setting

Control

value

range

mode

 

 

Torque command time constant

0

ms

0

T

Used to set the constant of a low pass filter in response to the torque

 

 

to

 

command.

 

 

20000

 

Torque

Torque command

 

 

 

 

 

After

 

 

filtered

TQC

TQC

Time

TQC: Torque command time constant

 

 

 

 

Station number setting

0

sta-

0

P S T

Used to specify the station number for serial communication.

 

tion

to

 

Always set one station to one axis of servo amplifier. If one station

 

 

31

 

number is set to two or more stations, normal communication cannot

 

 

 

 

be made.

 

 

 

 

Communication baudrate selection, alarm history clear

0000

 

0000h

P S T

Used to select the RS-422/RS-232C communication baudrate, select

 

 

to

 

various communication conditions, and clear the alarm history.

 

 

1113h

 

RS-422/RS-232C baudrate selection

0:9600 [bps]

1:19200[bps]

2:38400[bps]

3:57600[bps]

Alarm history clear

0:Invalid

1:Valid

When alarm history clear is made valid,

the alarm history is cleared at next power-on. After the alarm history is cleared, the setting is automatically made invalid (reset to 0).

RS-422/RS-232C communication standard selection

0:RS-232C used

1:RS-485 used

Communication response delay time

0:Invalid

1:Valid, reply sent after delay time of 800s or more

5 - 9

Page 106
Image 106