5. PARAMETERS

Class No.

Symbol

Name and function

39

VDC

Speed differential compensation

 

 

Used to set the differential compensation.

 

 

Made valid when the proportion control signal is switched on.

40For manufacturer setting Must not be changed.

41 *DIA Input signal automatic ON selection

Used to set automatic ON of SON, LSP and LSN.

0

Servo-on signal (SON) input selection 0: Switched on/off by external input.

1: Switched on automatically in servo amplifier.

(No need of external wiring)

Forward rotation stroke end signal (LSP) input selection

0:Switched on/off by external input.

1:Switched on automatically in servo amplifier.

 

 

 

 

(No need of external wiring)

 

 

 

 

Reverse rotation stroke end signal (LSN)

 

 

 

 

 

 

 

 

input selection

1

 

 

 

0: Switched on/off by external input.

parameters

 

 

 

1: Switched on automatically in servo

 

 

 

amplifier.

 

 

 

 

 

 

 

 

(No need of external wiring)

Expansion

42

*DI1 Input signal selection 1

 

0 0

 

 

 

Used to assign the control mode changing signal input pins and to set

 

 

the clear signal.

Control change signal (LOP) in- put pin assignment

Used to set the control mode change signal input connector pins. Note that this parameter is made valid when parameter No.

0 is set to select the position/spe- ed, speed/torque or torque/posi- tion change mode.

Set value

Connector pin No.

0CN1B-5

1CN1B-14

2CN1A-8

3CN1B-7

4CN1B-8

5CN1B-9

Clear signal (CR) selection

0:Droop pulses are cleared on the leading edge.

1:While on, droop pulses are always cleared.

Initial

Unit

Setting

Control

value

range

mode

 

980

 

0

P S

 

 

to

 

 

 

1000

 

0

 

 

 

0000

 

0000h

P S T

 

 

to

 

 

 

0111h

 

P S

0003

0000h

 

to

 

0015h

P/S

S/T

T/P

P S T

5 - 16

Page 113
Image 113
Mitsubishi Electronics MR-J2S- A instruction manual Used to set the differential compensation, Clear signal, 980 1000 0000