3. SIGNALS AND WIRING

 

 

 

 

 

(2) Output signals

 

 

 

 

 

 

 

 

 

Connec-

 

 

Control

 

 

 

I/O

 

mode

 

Signal

Symbol

tor pin

Functions/Applications

 

 

 

 

 

division

 

 

 

 

 

No.

 

P

S

T

 

 

 

 

Trouble

ALM

CN1B

ALM-SG are disconnected when power is switched off or the

DO-1

 

 

 

 

 

18

protective circuit is activated to shut off the base circuit. Without

 

 

 

 

 

 

 

alarm, ALM-SG are connected within 1 after power on.

 

 

 

 

Ready

RD

CN1A

RD-SG are connected when the servo is switched on and the servo

DO-1

 

 

 

 

 

19

amplifier is ready to operate.

 

 

 

 

In position

INP

CN1A

INP-SG are connected when the number of droop pulses is in the

DO-1

 

 

 

 

 

18

preset in-position range. The in-position range can be changed

 

 

 

 

 

 

 

using parameter No. 5.

 

 

 

 

 

 

 

When the in-position range is increased, INP-SG may be kept

 

 

 

 

 

 

 

connected during low-speed rotation.

 

 

 

 

Speed reached

SA

 

SA-SG are connected when the servo motor speed has nearly

DO-1

 

 

 

 

 

 

reached the preset speed. When the preset speed is 50r/min or

 

 

 

 

 

 

 

less, SA-SG are kept connected.

 

 

 

 

Limiting speed

VLC

CN1B

VLC-SG are connected when speed reaches the value set to any of

DO-1

 

 

 

6the internal speed limits 1 to 7 (parameters No. 8 to 10, 72 to 75) or the analog speed limit (VLA) in the torque control mode. They are disconnected when the servo-on signal (SON) switches off.

Limiting torque

TLC

TLC-SG are connected when the torque generated reaches the

DO-1

 

 

value set to the internal torque limit 1 (parameter No. 28) or

 

 

 

analog torque limit (TLA). They are disconnected when the servo-

 

 

 

on signal (SON) switches off.

 

Zero speed

ZSP

CN1B ZSP-SG are connected when the servo motor speed is zero speed

DO-1

19(50r/min) or less. Zero speed can be changed using parameter No. 24.

Electromagnetic

MBR

CN1B

Set "

1 " in parameter No. 1 to use this parameter. Note that

DO-1

 

 

 

 

 

 

 

 

 

brake interlock

 

19

ZSP will be unusable.

 

 

 

 

 

 

 

 

 

 

 

 

 

In the servo-off or alarm status, MBR-SG are disconnected.

 

 

 

 

 

 

 

 

 

 

 

 

 

When an alarm occurs, they are disconnected independently of

 

 

 

 

 

 

 

 

 

 

 

 

 

the base circuit status.

 

 

 

 

 

 

 

 

 

 

Warning

WNG

 

To use this signal, assign the connector pin for output using

DO-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parameter No.49. The old signal before assignment will be

 

 

 

 

 

 

 

 

 

 

 

 

 

unusable.

 

 

 

 

 

 

 

 

 

 

 

 

 

When warning has occurred, WNG-SG are connected.

 

 

 

 

 

 

 

 

 

 

 

 

 

When there is no warning, WNG-SG are disconnected within 1

 

 

 

 

 

 

 

 

 

 

 

 

 

second after power-on.

 

 

 

 

 

 

 

 

 

 

Battery warning

BWNG

 

To use this signal, assign the connector pin for output using

DO-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parameter No.49. The old signal before assignment will be

 

 

 

 

 

 

 

 

 

 

 

 

 

unusable.

 

 

 

 

 

 

 

 

 

 

 

 

 

BWNG-SG are connected when battery cable breakage warning

 

 

 

 

 

 

 

 

 

 

 

 

 

(AL.92) or battery warning (AL.9F) has occurred.

 

 

 

 

 

 

 

 

 

 

 

 

 

When there is no battery warning, BWNG-SG are disconnected

 

 

 

 

 

 

 

 

 

 

 

 

 

within 1 second after power-on.

 

 

 

 

 

 

 

 

 

 