Honeywell Switches Set Points from 1.1 to 22 Hg, Pressure Hg vacuum max Burst Pressure 150 PSI

Models: Switches

1 12
Download 12 pages 9.2 Kb
Page 6
Image 6

Set Points from 1.1” to 22” Hg

5000 Series Extended Duty Vacuum Switches With Direct Action Blade Contacts

The 5000 Series switch is specifically designed to stand up to extended duty applications. This switch is factory set. It features a fluorosilicone rubber diaphragm for compatibility with a wide variety of fluids, and various terminations including a Metri-Pack connector that forms a tight seal when connected. Among the outstanding design benefits are its durable construction, compact size, and enhanced set point integrity.

Standard Specifications

Type:

Direct action blade

 

contact

Contacts:

Silver alloy, gold plated

Set Point:

Factory set

Vacuum:

1.1 to 22” Hg

Operating

 

2.3” REF.

1.47” REF.

Switch Boot P/N 79380 for Vacuum and Pressure

Pressure:

30” Hg vacuum max.

Burst Pressure: 150 PSI

 

 

Ratings:

 

 

 

 

Resistive:

15

AMP-

6

VDC

 

8

AMP-

12

VDC

 

4

AMP-

24

VDC

Inductive:

1

AMP-

120

VAC

0.5AMP- 240 VAC Diaphragm: Fluorosilicone elastomer Temperature

Range: -40° F to + 250° F

Connector: 1/8-27 NPT male thread

Terminals: #8-32 screws, 1/4” blade,

280 Series Metri-Pack

Circuitry: SPST-N.O., N.C.

Base: Brass

Cover: Glass reinforced polyester

Options: Various base connector thread sizes; wire leads (potted & sealed).

5000 Series Switch

with Screw Terminals

 

5000 Series Vacuum Switch

 

 

 

Two Terminals

 

 

 

 

 

 

 

 

 

Internally Grounded

 

 

 

 

 

 

 

 

 

 

Part Number

 

 

Part Number

 

 

Contact Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuitry

 

Screw

Blade

 

 

Screw

Blade

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1-22” Hg

 

N.O.

 

78813

78814

 

 

77342

77344

 

 

 

 

N.C.

 

78815

78816

 

 

77343

77345

 

Standard set points are 2”Hg(27” H2O), 4”Hg, 9”Hg, and 17”Hg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Setting

 

Tolerance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1-3”Hg (15-41”H2O)

 

±.22”Hg(3”H2O)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-8”Hg

 

±1”Hg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9-17”Hg

 

±2”Hg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18-22”Hg

 

±3”Hg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Page 6
Image 6
Honeywell Switches manual Set Points from 1.1 to 22 Hg, Pressure Hg vacuum max Burst Pressure 150 PSI, Base Brass