System-specific wiring guides

Conventional systems

1H/1C System (1 transformer)

C24VAC common

R Power [1]

Rc [R+Rc joined by jumper] W Heat relay

Y Compressor contactor **

G Fan relay **

Heat Only System [3]

C24VAC common

R Power [1]

Rc [R+Rc joined by jumper] W Heat relay

Heat Only System With Fan [4]

C24VAC common

R Power [1]

Rc [R+Rc joined by jumper]

See [notes] below.

1H/1C System (2 transformers)

C24VAC common

R Power (heating) [1] Rc Power (cooling) [1, 2] W Heat relay

Y Compressor contactor **

G Fan relay **

2H/2C System (1 transformer) [6]

C24VAC common

R Power [1]

Rc [R+Rc joined by jumper] W Heat relay (stage 1)

W2 Heat relay (stage 2)

Y Compressor contactor (stage 1) ** Y2 Compressor contactor (stage 2)

G Fan relay **

W

 

Heat relay

 

2H/2C System (2 transformers) [6]

G

 

Fan relay

 

C

24VAC common

 

 

 

 

 

 

Cool Only System [5]

R

Power (heating) [1]

Rc

Power (cooling) [1, 2]

 

 

 

 

 

 

 

 

 

 

C

 

24VAC common

W

Heat relay (stage 1)

 

 

 

 

 

 

R

 

Power [1]

 

W2

Heat relay (stage 2)

 

 

Rc

 

[R+Rc joined by jumper]

 

Y

Compressor contactor (stage 1) **

 

 

Y

 

Compressor contactor **

 

Y2

Compressor contactor (stage 2)

 

 

 

 

 

 

G

 

Fan relay **

 

G

Fan relay **

**[See note on page 4]

[1]

Power supply. Provide disconnect means and overload protection as required.

[2]

Remove jumper (R to Rc) for systems with two transformers. Common connection

 

must come from cooling transformer.

[3]

In Installer Setup, set

system type to Heat Only, No Fan.

[4]

In Installer Setup, set

system type to Conventional with zero cooling stages.

[5]

In Installer Setup, set

system type to Conventional with zero heat stages.

[6]

In Installer Setup, set

system type to Conventional with 2 heat AND 2 cool stages.

[7]

In Installer Setup, set changeover valve to O or B.

[8]

In Installer Setup, set to Heat Pump with 1 compressor stage and no auxiliary heat stages.

[9]

In Installer Setup, set to Heat Pump with 1 compressor stage and 1 auxiliary heat stage.

[10] In Installer Setup, set to Heat Pump with 2 compressor stages and no auxiliary heat stages.

[11] In Installer Setup, set to Heat Pump with 2 compressor stages and 1 auxiliary heat stage.

[12] “L” terminal sends a continuous output when thermostat is set to Em. Heat, and acts as a system monitor when in Heat, Cool or Off modes.