The Thor VM2 can be connected to vehicle power as follows:
•Direct power connection
•Replace a previously installed VX6/VX6 or Thor VX8/VX9 with an adapter cable. See Adapter Cables, below.
•High voltage forklifts (over 60V). Refer to the “DC/DC Power Supply Installation Instructions,” available at www.honeywellaidc.com.
Connecting the Power Cable
The following power option is for
!
!
CAUTION - For installation by trained service personnel only.
Fuse RequirementsWARNING - For proper and safe installation, the input power cable must be connected to a fused circuit on the vehicle. If the supply connection is made directly to the battery, the fuse should be installed in the positive lead within 5 inches of the battery’s positive (+) terminal. The fused circuit requires a maximum time delay (slow blow) fuse with a current rating as noted below.
•For 12VDC input, use a 10A slow blow fuse that has a DC voltage rating greater than 12VDC.
•For 24VDC input, use a 6A slow blow fuse that has a DC voltage rating greater than 24VDC.
•For 36VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 36VDC.
•For 48VDC input, use a 3A slow blow fuse that has a DC voltage rating greater than 48VDC.
Note: For North America, a UL Listed fuse must be used.
•Route the power cable away from the outside of the forklift.