Fused electrical supply is requi red-copper wire only. Time delay fuse or circuit breaker recommended and provide separate circuit serving only this appliance. Outlet should be placed in adjacent cabinet.

Make sure that the plug on the appliance remains accessible after installation.

After making sure that the voltage and the frequency values for the current i n the home correspond to those on the rating plate and that the electrical system is sized for the maximum voltage on the rating plate, insert the plug into an electrical socket which is earthed properly. If the electrical socket to which the appl iance must be connected is not appropriate for the plug , replace the socket(installed by a qualified electrici an),rather than using a adaptors or the like as they coul d cause overheating and burns.

The appliance must be connected to the water mains using new hose-sets. The old hose-sets should not be reused.

Water pressure must be between 0,04 MPa and 1 MPa. If the pressure is below the minimum consult our Service Department for advice.

If faucet has not threads: attach the faucet adapter to faucet, then tighten every screw of the adapter. To prevent leaking your should tighten the adapter.

1Pull Unicouple and its hoses completely out from storage compartment located at rear of dishwasher

and attach it to the faucet adapter.

Connector of Model

2

3

Attach the Unicouple connector to the faucet adapter by depressing the collar at the top of the connector.

When Unicouple is all the way up onto the adapter, release the collar. It will then snap Into position to

lock the Unicouple in place. The Unicouple' s small hose carries water from the faucet to the dishwasher. Its large hose carries drain water to the sink. Be sure Unicouple is pointing toward the sink bowl drain opening and the sink drain is open for water that will drain from your dishwasher. If your dishwasher drains into a disposer, operate the disposer until it is completely empty before starting the dishwasher.

Turn water fully on before starting the dishwasher.

A hose that attaches to a sink spray can burst if it is installed on the same water line as the dishwasher. If your sink has one, it is recommended thet the hose be disconnected and the hole plugged.

1

2

3

Turn off the water.

Release the water pressure by depressing the pressure release button. This relieves water pressure and protects you, and the room, from severe splashing.

Release Unicouple from faucet by depressing the collar at the top of the Unicouple connector.

1

2

Remove the power cord plug from the wall receptacle. Disconnect Unicouple from faucet adapter.

10

Page 12
Image 12
Hoover HEDS 668-80, HEDS 668S-80 manual

HEDS 668S-80, HEDS 668-80 specifications

The Hoover HEDS 668-80 and HEDS 668S-80 are advanced sensor modules widely recognized for their precision and reliability in various applications. Both models serve prominently in the realm of motion detection and optical encoders, making them indispensable in robotics, industrial automation, and consumer electronics.

At the core of these sensors is the use of integrated photodetectors and light emitters, which work together to accurately capture motion data. The HEDS 668-80 features a compact design, allowing for easy integration into numerous hardware configurations. It incorporates a dual-channel output, which provides both quadrature and single-ended output signals. This feature enables enhanced motion control and allows for more accurate detection of direction, making it suitable for applications requiring precise angular measurements.

One of the standout technologies in the HEDS series is its use of reflective optical sensing. This technology minimizes interference from ambient light conditions, ensuring reliable performance even in varying environmental settings. The sensors are designed with a resolution of up to 500 counts per revolution, allowing for finely-tuned control in robotic applications.

The HEDS 668S-80 enhances the capabilities found in the 668-80 model by offering an increased tolerance for temperature variations and shock resistance. This makes it an ideal candidate for harsh operating conditions, where reliability is paramount. The HEDS 668S-80 also boasts an improved response time, further enhancing the performance in high-speed applications.

Both models feature a straightforward mounting system that facilitates installation and adjustment, allowing engineers to set up their systems quickly and efficiently. Additionally, their robust construction ensures durability across extended periods of use, providing a long lifespan in demanding applications.

In summary, the Hoover HEDS 668-80 and HEDS 668S-80 represent advanced sensor technology that combines high performance with robust design. Their integrated features cater to a variety of applications, making them a vital component in the ever-evolving landscape of automated systems and precision measurement. As industries increasingly rely on automation, these sensors offer the reliability and accuracy that engineers need to achieve optimal performance in their projects.