![](/images/new-backgrounds/1050360/5036053x1.webp)
Agitator brush rolI
When to replace
Disconnect cleaner from eiectri- cal outiet and detach hose from cleaner.
When agitator brushes are worn, the brush roll should be replaced.
To check condition of brushes, move edge of card across bottom plate while turning agitator. To maintain cleaning effectiveness, replace brush roll if brushes do not touch card.
What to buy
The brush roll may be replaced with either a single or double brush roll.
Single row of brushes - Hoover part No.
Double row of brushes -
Hoover part No. 48414432
How to replace
Disconnect cleaner from ekctri- cai outiet and detach hose from cleaner.
1.Remove bottom plate as de- scribed in ‘The belt. section. Remove agitator from cleaner.
2.Turn end plates of agitator in opposite directions until one end plate comes off.
24